3onedata ICS5530 Series Snelle installatiehandleiding - Pagina 2

Blader online of download pdf Snelle installatiehandleiding voor {categorie_naam} 3onedata ICS5530 Series. 3onedata ICS5530 Series 3 pagina's. Industrial core layer 3 ethernet switch

Step 3
Place the device in the rack; adopt 4 bolts to fix
two sides mounting lugs in the rack.
Step 4
Check and confirm the product is mounted firmly
on the rack, then mounting ends.
【Disassembling Device】
Step 1
Power off the device.
Step 2
Adopt screw driver to loosen the 4 bolts fixed on
the mounting lugs in the rack.
Step 3
Shift out the device from rack, disassembling
ends.
Notice before Powering on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug and power on.
Power switch "—" means power ON, "O" means
power OFF.
Power OFF operation: First, put the powers switch to
the "O" side and then disconnect the power supply.
Finally disconnect the connector between the device
and the power cord. Please notice the operation order
above.
【Power Supply Connection】
AC power supply
Model I provides 2 AC power supply access
interfaces which come with a switch.
Power supply range: 100~240VAC/DC.
DC power supply
Model II supports 2 DC power input
interfaces, and adopts 5-pin 5.08mm
pitch terminals, and the power supply
occupies the left 3 pins. The power supply supports
anti-reverse connection and dual power supply redundancy,
and the pin definitions of power supply are shown in the left
figure. Power input range: 18~72VDC.
【Restore Default Settings】
RESET is restoring default settings button. Device Restoring
default settings steps as follows: press and hold the RESET
button, power on the device again, wait for about 3~4
seconds to restore the factory settings.
【Relay Connection】
R+ and R- are the relay alarm output
section. They are open circuit in normal
non alarm state, closed when any alarm
information occurs. The product supports 2-way relay alarm
output, externally connected to alarm lights or alarm buzzer
or other switching value collecting device in order to timely
notify operators when the alarm occurs.
【Console Port Connection】
The device provides 1 program debugging port based on
RS-232 serial port which can conduct device CLI command
management after connecting to PC. The interface adopts
RJ45 port, and the RJ45 pin definitions are as follows:
Pin No.
2
3
Definition
TXD
RXD
【Checking LED Indicator】
The series product provides LED indicators to monitor the
device working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Indicate
ON
P1
OFF
ON
P2
OFF
Blinking
RUN
OFF
ON
ON
ALM
OFF
ON
Link
(G1-G24,
Blinking
X1-X6)
OFF
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below.
Step 1
Configure the IP addresses of computer and the
5
device to the same network segment, and the
GND
network
accessed.
Step 2
Enter device's IP address in the address bar of
the computer browser.
Description
PWR
is
connected
and
running normally
Power supply is disconnected
or running abnormally
PWR
is
connected
and
running normally
Power supply is disconnected
or running abnormally
The
system
is
running
normally
The system is not running or
running abnormally
System is running abnormally
Power supply, port link alarm
Power supply, port link without
alarm
Port has established valid
network connection
Port
is
in
a
network
communication status
Port hasn't established valid
network connection.
between
them
can
be
mutually