3onedata ICS5530-16GS8GC6XS-2P220 Snelle installatiehandleiding - Pagina 2
Blader online of download pdf Snelle installatiehandleiding voor {categorie_naam} 3onedata ICS5530-16GS8GC6XS-2P220. 3onedata ICS5530-16GS8GC6XS-2P220 3 pagina's. Industrial layer 3 ethernet switch
Ook voor 3onedata ICS5530-16GS8GC6XS-2P220: Snelle installatiehandleiding (3 pagina's)
Step 3
Place the device in the rack; adopt 4 bolts to fix
two sides mounting lugs in the rack.
Step 4
Check and confirm the product is mounted firmly
on the rack, mounting ends.
【
】
Step 1
Device power off.
Step 2
Adopt screw driver to loosen the 4 bolts fixed on
the mounting lugs in the rack.
Step 3
Shift out the device from rack, disassembling
ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and
power on.
Power switch "—" means power ON, "O" means
power OFF.
Power OFF operation: First, put the powers switch to
the "O" side and then disconnect the power supply.
Finally disconnect the connector between the device
and the power cord. Please notice the operation order
above.
【Power Supply Connection】
AC power supply
This device provides 2 AC power supply access
interfaces which come with a switch.
Power supply range: 100~240VAC/DC.
【Restore Factory Settings】
RESET is restoring default settings button. Device Restoring
default settings steps as follows: press and hold the RESET
button, power on the device again, wait for about 3~4
seconds to restore the factory settings.
【Relay Connection】
R+ and R- are the relay alarm output
section. They are open circuit in normal
non alarm state, closed when any alarm
information occurs. The product supports 2-way relay alarm
output, externally connected to alarm lights or alarm buzzer
or other switching value collecting device in order to timely
notify operators when the alarm occurs.
【Console Port Connection】
The series products provide 1 program debugging port
based on RS-232 serial port which can conduct device CLI
command management after connecting to PC. The
interface adopts RJ45 port, the RJ45 pin definition as
follows:
Pin No.
2
3
Definition
TXD
RXD
【Checking LED Indicator】
The series products provide LED indicators to monitor the
device working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Indicate
Description
PWR is connected and running
ON
normally
P1
PWR is disconnected and
OFF
running abnormally
PWR is connected and running
ON
normally
P2
PWR is disconnected and
OFF
running abnormally
Blinking
System runs normally
RUN
The system is not running or
OFF
running abnormally
LED
Indicate
ON
ON
ALM
OFF
ON
Link
(G1-G24,
Blinking
X1-X6)
OFF
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Configure the IP addresses of computer and the
device to the same network segment, and the
5
network between them can be mutually accessed
GND
Enter device's IP address in the address bar of
Step 2
the computer browser.
Enter device's user name and password in the
Step 3
login window as shown below.
Description
System is running abnormally
Power supply, port link alarm
Power supply, port link without
alarm
Port has established valid
network connection
Port is in a network
communication status
Port hasn't established valid
network connection.