Absolute Process Instruments API 1025 G Snelstarthandleiding
Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Absolute Process Instruments API 1025 G. Absolute Process Instruments API 1025 G 2 pagina's. 4-20 ma input alarm trips with loop supply
4-20 mA Input Alarm Trips with Loop Supply
Input:
4-20 mADC
Output:
One 8 Amp DPDT Relay or Two 8 Amp SPDT Relays
O 4-20 mA Input with Loop Supply
O Field Adjustable Setpoints
O Plug-In Design for Fast Installation
O Input LoopTracker
and Alarm Status LEDs
®
O Alarm Test, Optional Reset Button
Applications
Q Process Limit Backup Alarm
Q Tank Level Alarm
Q Process Signal Over, Under, Out-of-Range Alarm
4-20 mA Input
Factory configured 4-20 mADC, sourcing
Input Impedance and Burden
50 Ω typical
Current:
Voltage burden:
1.25 VDC at 20 mA current input
Isolation and Input Protection
750 VAC
or 750 VDC common mode protection
p
Input isolated from power supply
Input Loop Power Supply
18 VDC unregulated, 25 mADC, <1.5 V
p-p
LoopTracker
Variable brightness LED indicates input loop level and status
API 1005 G Relay Output
Two SPDT form C contact sets operating in unison as one
DPDT contact set
One setpoint, 12 turn potentiometer, 0-100% of span
Factory configured alarm type
Standard: HI alarm, non-latching, normal acting
Options: LO alarm, latching, reverse acting
API 1025 G Relay Output
Two independent SPDT form C contact sets
Two setpoints, two 12 turn potentiometers, 0-100% of span
Factory configured alarm action
Internal jumpers for HI/LO, LO/LO, HI/HI, LO/HI
Standard: HI/LO alarm, non-latching, normal acting
Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting
Relay Contact Rating
8 A @ 240 VAC resistive load or 30 VDC resistive load
5 A @ 240 VAC inductive load (cos f = 0.4)
3.5 A @ 30 VDC inductive load (L/R = 7ms)
See graph on other side for relay load ratings
Caution: Do not exceed socket voltage rating
Use an RC snubber for inductive loads
Deadband
Alarm trip/reset window is symmetrical about the setpoint
API 1005 G
1.0 to 100% of span, 12 turn potentiometer.
API 1025 G
Fixed at 1% of span, standard
API 1025 G A Adjustable deadbands, 1.0 to 100% of span,
1 turn potentiometer for each setpoint
Output Test/Reset Button
Toggles relay(s) to opposite state when pressed
Resets latching relay with HT option, available on 1005 G only
Response Time
70 milliseconds typical
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than 0.02% of span per °C stability
Housing and Sockets
IP 40, requires installation in panel or enclosure
API 011 or API 011 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted
Power
Standard:
115 VAC ±10%, 50/60 Hz, 2.5 W max.
P option:
85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W typ.
A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.
D option:
9-30 VDC, 2.5 W typical
A
P
BSOLUTE
ROCESS
Variable Brightness Input LED
Bi-Color Relay LED
Deadband Adjustment
Setpoint Adjustment
Output Test Button
Reset w. HT Option
API 1005 G
A Option Deadband Adjustments
Variable Brightness Input LED
Bi-Color Relay 2 LED
Bi-Color Relay 1 LED
Setpoint 2 Adjustment
ripple
Setpoint 1 Adjustment
Output Test Button
API 1025 G
Description
The API 1005 G and API 1025 G are factory configured for a
4-20 mA current input and provides alarm contact outputs.
The 4-20 mA input provides power to the input loop via a
built-in 18 VDC loop power supply that can be used to power a
loop-powered transmitter or other passive input device. Heavy
duty relay contacts allow directl control of high capacity loads.
The API 1005 G provides a single setpoint adjustment and
DPDT relay contacts. The alarm output can be factory config-
ured for HI or LO operation, non-latching or latching, normal
or reverse acting. Top-accessible potentiometers are used to
adjust the alarm setpoint and deadband.
The API 1025 G contains two independent setpoints with two
SPDT relay contact outputs. The alarm output can be factory
configured for HI/HI, HI/LO, LO/HI or LO/LO operation, normal
acting or reverse acting. Top-accessible potentiometers are
used to adjust each alarm setpoint. Deadband is fixed at 1% of
span. Adjustable deadbands are optional.
Model
API 1005 G
API 1005 G A230
API 1005 G P
API 1005 G D
API 1025 G
API 1025 G A230
API 1025 G P
API 1025 G D
Options—add to end of model number
L
1005 G with LO trip. Alarm trips on decreasing signal.
HT 1005 G latching alarm with push button reset
HP 1005 G latching alarm with power-off reset
Module power must be turned off to reset alarms
HH 1025 G with HI/HI trip. Alarms trip at their respective
trip points on increasing signal.
LL
1025 G with LO/LO trip. Alarms trip at their respective
trip points on decreasing signal.
A
1025 G with adjustable deadbands
R
Reverse-acting alarms. Relay coils energized in an alarm
condition. No alarm condition with module power off.
U
Conformal coating for moisture resistance
I
NSTRUMENTS
2.38"
1.75"
2.38"
1.75"
LoopTracker and Alarm Status LEDs
API exclusive features include a LoopTracker LED that varies in
intensity with changes in the process input signal.
A red/green bi-color alarm status LED (two on the API 1025
G) visually indicate alarm status. These LEDs provide a quick
visual picture of your process at all times.
Output Test/Unlatch
API's exclusive functional test button can be used to verify the
alarm and system operation. The output test button greatly
aids in saving time during initial startup and/or troubleshooting.
The HT latching option provides the additional function of
unlatching the alarm when the reset button is pressed. The
alarm will reset if the alarm condition not longer exists.
Input
Standard Alarm Configuration
Factory ranged
Single setpoint one DPDT relay
4-20 mA
HI alarm, non-latching, normal acting
Factory ranged
2 setpoints, 2 SPDT relays
4-20 mA
HI/LO alarms, non-latching, normal acting
Accessories—order as a separate line item
API 011
API 011 FS 11-pin finger safe socket, DIN rail or surface mount
API CLP1
API 011 FS
300 V Rating
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
API 1005 G, API 1025 G
Hot Swappable
Plug-In Design
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
Free Factory
Quick Link
api-usa.com/1005
I/O Setup!
Power
115 VAC
230 VAC
85-265 VAC or 60-300 VDC
9-30 VDC
115 VAC
230 VAC
85-265 VAC or 60-300 VDC
9-30 VDC
11-pin socket, DIN rail or surface mount
Module hold-down spring for high vibration or
mobile applications
API 011
API CLP1
300 V Rating
api-usa.com
2.75"
© 08-19