AddEnergie CoRe+PSV2 Installatiehandleiding - Pagina 6

Blader online of download pdf Installatiehandleiding voor {categorie_naam} AddEnergie CoRe+PSV2. AddEnergie CoRe+PSV2 14 pagina's.

Installation and Safety

INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR ELECTRIC SHOCK
IMPORTANT SAFETY INSTRUCTIONS - PLEASE DO NOT DISCARD THESE INSTRUCTIONS
WARNING – When using electric products, basic precautions should always be followed, including the
following. This manual contains important instructions for Model CoRe+ that shall be
followed during installation, operation and maintenance of the unit.
Always use a manual screwdriver only; DO NOT use an impact driver for the screws at any times, otherwise,
it will void the warranty.
Carefully read this guide before installing the EVSE
1- CAUTION - To reduce the risk of fire, connect only to a circuit provided with 40 amperes maximum branch circuit
overcurrent
protection in accordance with the Canadian Electrical Code (CSA C22.1-12) and the National
Electrical Code (ANSI/NFPA 70).
2- This EVSE was designed to be ground-based, wall-mounted or post-mounted.
3- You must make sure that the types of mounting surface of the wall or the post will be strong enough to bear the
minimum weight of the EVSE 15 kg (33 lbs) and their anchors must be compatible with the type of mounting surface.
4- Verify with local authorities that the location where the EVSE is to be installed is free from underground pipelines
or electrical equipment, otherwise you might inflict yourself serious injuries.
5- Connect the power supply of the EVSE with caliber 6 to 8 copper conductors rated for usage at a temperature of
at least 75°C.
6- This product must be connected to a grounded, metal, permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead
on the product and installed by a certified electrician.
7- Communicate with a certified contractor, certified electrician or trained installer to ensure compliance with local
building code, regulation, security standards and weather conditions.
8- Any EVSE part alteration will automatically void the warranty.
9- Handle parts with care, since they can be sharp-edged. Always use safety glasses and gloves when unpacking
and installing.
10- Do not install on or over a combustible surface.
11- The power supply cables of the EVSE shall be rated FT2 minimum.
12- The input cable strain relief, conduit or armed-cable bushings and adapter:
A. have to be certified for both Canada and US.
B. have to be waterproof (NEMA 4X).
C. have to be suitable for the outside diameter of the chosen cable and suitable for mounting into a 34.5 mm
(1,36 in) diameter opening (for connection through the bottom cable opening).
IMPORTANT SAFETY INSTRUCTIONS
This device should be supervised when used around children.
Never insert your finger into the electric vehicle connection.
Never use the EVSE if the flexible power cord or EV cable is frayed, has broken insulation, or any other signs of damage.
Never use the EVSE if the enclosure or the EV connector is broken, cracked, open, or shows any other signs of damage.
This EVSE was designed to be used with electric vehicles equipped with a SAE-J1772 connector.
This EVSE is to be used to charge vehicles that do not require a ventilated environment during charging.
Make sure to always disconnect the power supply of the EVSE before servicing.
2016 ADDÉNERGIE TECHNOLOGIES INC. ALL RIGHTS RESERVED. Information and Specifications Contained in this Document are Subject to Change, Amendments, and Additions at any Time, Without Notice
6