Aube Technologies TI032-3W Installatie- en gebruikershandleiding
Blader online of download pdf Installatie- en gebruikershandleiding voor {categorie_naam} Aube Technologies TI032-3W. Aube Technologies TI032-3W 2 pagina's. Aube technologies inc. programmable wall switch installation and user guide
Ook voor Aube Technologies TI032-3W: Installatie-instructies en gebruik (2 pagina's)
Applications
The TI032-3W switch can be used in a single-pole or 3-way installation
with the following types of lighting:
• Incandescent
• Halogen
• Low-voltage halogen with transformer
• Fluorescent
The TI032-3W switch cannot be used with a load below 40 W or above
500 W.
Installation
Cut power at the circuit breaker to avoid electric shock.
Remove the existing switch. (For a 3-way installation, identify and
label the wire that is connected to the "common" screw.)
Install the new switch (refer to the appropriate section below).
Apply power at the circuit breaker.
NOTE A:
The white wire is not the neutral wire but the wire going to the
load.
SINGLE-POLE INSTALLATION
120 VAC
Neutral
120 VAC
Connect wires "2" and "C" of the TI032-3W to the line (120 V) wire.
EXISTING 3-WAY INSTALLATION
120 VAC
Jumper
Connect wire "C" of the TI032-3W to the "common" wire, identified when
removing the old switch. Connect the other two TI032-3W wires to the
two remaining wires.
At the other 3-way switch, connect the jumper wire between the "com-
mon" screw and the screw where wire "1" of the TI032-3W is connected.
TI032-3W
Line
See NOTE A
Line
Neutral
See NOTE A
Red
Red
3-wire cable
1.
NEW 3-WAY INSTALLATION
120 VAC
2.
The jumper wire is not required in this installation. A single-pole
switch can be used as the other switch in a 3-way installation.
Power-On
Pry the switch door open from the
bottom using a small screwdriver.
Ensure the ON/OFF selector is set
to ON.
Reset the switch using a paper clip.
0:00 and MO will flash.
If the display is blank:
•
Ensure the ON/OFF selector is properly engaged in the ON posi-
tion. Push it to the right using a small screwdriver.
•
If the programmable switch controls a lamp equipped with a
built-in On/Off switch, ensure the lamp switch is set to On.
•
Ensure the light bulb is not burned out and is tightly screwed in its
socket.
EXISTING 3-WAY INSTALLATION
If either switch does not work properly, rewire the jumper between the
"common" screw and the other screw.
WARNING: Before replacing the light bulb, place the ON/OFF
selector in the OFF position. Failure to do so might damage the
switch.
Setting the Clock
NOTE: The switch displays the time in 24-hour format by default or
following a reset.
To change to 12-hour format (or vice versa), proceed as follows:
a) Press one of the control buttons to ensure the MAN or
AUTO indicator is displayed.
b) Press the MIN and HOUR buttons simultaneously and brief-
tly (0:00 display = 24-hour, 12:00 display = 12-hour ).
Set the time using the HOUR and MIN buttons. If you have
selected the 12-hour format, ensure that PM appears on the
screen when an afternoon time is displayed.
Set the day by using the DAY button.
Press one of the control buttons or close the switch door to
return to normal operation.
TI032-3W
Installation and User Guide
Programmable Wall Switch
See NOTE A
400-032-001-B
30/11/06
3.
Reset
Control (4)
On/Off
selector
4.
1/2