3onedata IPS3110 Series Snelle installatiehandleiding - Pagina 2

Blader online of download pdf Snelle installatiehandleiding voor {categorie_naam} 3onedata IPS3110 Series. 3onedata IPS3110 Series 3 pagina's. Unmanaged industrial ethernet switch

3onedata IPS3110 Series Snelle installatiehandleiding
Check whether the DIN-Rail mounting kit that
comes with the device is installed firmly.
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Check and confirm the product is firmly installed on
DIN-Rail, and then mounting ends.
【Disassembling DIN-Rail】
Power off the device.
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, and then
power on.
Power OFF operation: first unpin the power plug, and
then remove the power line, please note the operation
order above.
【Power Supply Connection】
48VDC Power Supply
The top panel of this switch provides 4-pin DC power supply
input terminal blocks, and supports redundant power supply
input function. It provides two pairs
of power supply input terminals,
PWR1 and PWR2, which could be
used individually or connected to
two independent DC power supply
systems. It uses two pairs of
terminal blocks to connect to the device at the same time.
When any one of the power supply systems fails, the device
could operate normally without interruption, which has
improved the reliability of network operation. Voltage input is
48VDC (the definitions of terminal are V1-, V1+, V2-, and V2+).
The power supply supports anti-reverse connection.
24VDC Power Supply
The top panel of this switch
provides 4-pin DC power supply
input terminal blocks, and supports
redundant
function. It provides two pairs of
power
supply
PWR1 and PWR2, which could be used individually or
connected to two independent DC power supply systems. It
uses two pairs of terminal blocks to connect to the device at
the same time. When any one of the power supply systems
fails, the device could operate normally without interruption,
which has improved the reliability of network operation.
Voltage input is 24VDC (the definitions of terminal are V1-,
V1+, V2-, and V2+). The power supply supports anti-reverse
connection.
【Relay Connection】
The access terminal of this relay is located
on the top panel of the device. Relay
terminal blocks are a pair of normally open
contacts in the alarm relay of the device.
They are open circuit in the status of normal
no alarm, and closed when any warning message occurs. The
product supports 1 relay warning message output, and
warning messages output of the DC power supply or network
abnormal alarm output. It can be connected to alarm indicator,
alarm buzzer, or other switching value collecting devices for
timely warning operating staffs when the warning message
occurs.
【DIP Switch Settings】
DIP switches definitions as follows:
Model I
DIP
1
2
3
4
power
supply
input
Model II
DIP
input
terminals,
1
2
3
4
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
PWR1
PWR2
The products provide 4 pins DIP switch for
function settings, where "ON" is the enable valid
terminal.
Definition
Operation
Flow control
Set the DIP switch to ON
RJ45 specified 10M
Set the DIP switch to ON
Port alarm
Set the DIP switch to ON
100M/Gigabit
Set the DIP switch to ON
switching of fiber
(ON is 100M)
port
Definition
Operation
Flow control
Set the DIP switch to ON
Port alarm
Set the DIP switch to ON
RJ45 specified 10M
Set the DIP switch to ON
VLAN (G2 can
Set the DIP switch to ON
communicate with
other ports, but other
ports cannot
communicate with
each other)
Status
Description
PWR1 is connected and running
ON
normally
PWR1 is disconnected and
OFF
running abnormally.
PWR2 is connected and running
ON
normally
OFF
PWR2 is disconnected and