Auber Instruments WS Series Bedienings- en instructiehandleiding - Pagina 2

Blader online of download pdf Bedienings- en instructiehandleiding voor {categorie_naam} Auber Instruments WS Series. Auber Instruments WS Series 18 pagina's. Programmable pid temperature controller with dual probe
Ook voor Auber Instruments WS Series: Beknopte handleiding (15 pagina's), Beknopte handleiding (14 pagina's), Bedienings- en instructiehandleiding (18 pagina's), Beknopte handleiding (14 pagina's)

Auber Instruments WS Series Bedienings- en instructiehandleiding
operation. If the sensor is left outside, the controller will assume the temperature
is low even if the controlled subject is already very hot. The controller will provide
full power to the heater, which will not only overheat the controller, but also
damage your appliance or even cause a fire. If the sensor is not permanently
mounted on the system and left outside of the system, there is a potential problem.
You should enable the open loop alarm function (see page 11 for details).
 This controller is designed to control the devices recommended by Auber
Instruments only. Using it to control a non-recommended device can be
dangerous and cause fire. Auber Instruments is not liable for damages caused by
misuse of the controller. If you are not sure whether the controller can be used,
please contact Auber Instruments before use.
 If an abnormal display or noise is observed, turn the controller off, unplug the
power cord and contact the manufacturer before using it again.
 Clean the controller only when it is cool and unplugged.
 Do not allow children to operate the controller.

Specifications

Input voltage:
Output voltage:
Maximum Current:
Fuse Size:
Control Action:
Control Mode
Output switching device:
Sensor type:
Sensor tip dimensions:
Sensor cable length,
Alarm:
Timer Range:
Temperature display unit:
Temperature resolution:
Temperature display range: -50 to 400 ° C or -58 to 752 ° F.
Temperature accuracy:
Dimension:
Weight:
Warranty:
100 to 240 VAC 50 /60 Hz.
Same as the input.
15A at 120V, 10A at 240V
20A Fast blow.
Heating (reversed action) or cooling (direct action).
PID, PI, PD, P or On/off.
Built-in optically isolated solid state relay with zero voltage
crossing switching.
Pt100 RTD sensor.
4 mm diameter x 40 mm long.
3 ft (915 mm).
High limit alarm and Open loop alarm with LED and
buzzer.
1 to 9999 minutes. It can be turned off by user.
Celsius or Fahrenheit.
1 ° C or 1 ° F.
+/-1° C in 10 to 100 ° C range
6 x 3.2 x 7 inch (155 x80x170 mm) W x H x D.
2.9 lb (1.3 kg).
1 year for controller, 90 days for sensor.
2