ADDER AdderLink Infinity 2112T Snelstarthandleiding - Pagina 2
Blader online of download pdf Snelstarthandleiding voor {categorie_naam} ADDER AdderLink Infinity 2112T. ADDER AdderLink Infinity 2112T 4 pagina's. Adderlink infinity
ALIF 2112T - front panel
VNC port
• VNC On when a VNC viewer is connected.
• SER On when the serial port is enabled and active.
• AUD On when audio is enabled and active.
• USB On when USB is enabled and active.
• DVI On when DVI video is enabled and active.
• PWR Power indicator.
ALIF 2112T - rear panel
INDOOR
USE ONLY
DVI-D-1
OPTIONS
1
2
ON
1 2
5V
2.5A
Power
USB
Primary video
input
port
Configuration
switches
Indicators
Infinity port
DVI-D-2
IN
COMPUTER
Audio
Secondary
input
video
line
input
in/out
Infinity port configuration
• If ALIF TX and RX units are directly connected, no configuration
action is required, provided that they have their factory default
settings in place. If the standard settings have been changed in a
previous installation, you merely need to perform a factory reset
on each unit (see below).
• Where ALIF units are connected via network links, you will need
to specify their network address details. This can be done by
connecting a computer system temporarily to each ALIF unit
and using the Infinity browser-based configuration utility. This
configuration utility also allows numerous other settings to be
altered.
Note: For basic one-to-one installations, the factory default
addresses may be acceptable for immediate use within your
network without the need to use a configuration utility or change
their values: TX unit (169.254.1.33), RX unit (169.254.1.32).
Manual factory reset
Use to return an ALIF 2112T unit to its default configuration.
1 Remove power from the ALIF unit.
2 Locate the small hole on the front panel, next to the left-hand
Ethernet socket.
AUX
3 Push a narrow implement (e.g. a straightened-out paper clip) into
OUT
the hole and hold it in. Meanwhile, power on the unit.
After around eight seconds, when the factory reset has
completed, five of the front panel indicators will flash for a period
of three seconds to indicate a successful reset operation.
4 Remove the implement and then re-apply power to start the unit
in its default configuration.
AUX
(serial)
port