Elite SOLDAmaq 30 Gebruikershandleiding - Pagina 15

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Elite SOLDAmaq 30. Elite SOLDAmaq 30 18 pagina's.

Elite SOLDAmaq 30 Gebruikershandleiding

5.2.Electrical connection

DANGER HIGH VOLTAGE!
SOLDAmaq welding machines must be strictly connected to the voltage indicated in the machine
order and on the machine itself. The connection to a voltage other than that indicated may cause a
breakdown in the machine and represents a risk for people who use the machine.
For its connection to the electrical network, the machine requires only two phases and the ground
connection.
This installation must be carried out by qualified technical personnel and checked with a voltage
meter before turning on the machine.
It is absolutely essential that the cross-section of the connection cable is as required, that the machi-
ne has a dedicated socket protected against overloads and that it is as close as possible to the socket.
In case of an inadequate section of the cable, not enough current will reach the machine at the time
of welding, causing a defective and extremely fragile weld. This is one of the most important points
since a very high number of possible welding problems is due to this problem.
We reject any responsibility for a wrong connection.
Once the connection has been made and checked, turn the main ON/OFF switch to the ON position.
Check before start-up that the soldering iron voltmeter indicator is at the selected voltage value with
a difference of no more than 5%, and that this value is stable.
Joan Oró, 27 Pol. Ind. Sesrovires- St. Esteve Sesrovires, BCN, España– +34 932 935 178 – !