Elite Core DM-8 Gebruikershandleiding - Pagina 17

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Elite Core DM-8. Elite Core DM-8 20 pagina's. Personal monitoring system

Elite Core DM-8 Gebruikershandleiding
Elite Core PM-16 User Guide
PM-16 System Connections
The PM-16 Personal Monitoring devices use standard CAT5E cables, and work with the Neutrik™
Ethercon connector for added protection and stability. We recommend a maximum cable length of
500 ft (150 m).
All PM-16 systems must use an IM-16 Input Module and one or more PM-16 Personal Mixers. We
recommend using the DM-8 Distribution Module to deliver audio and power to the PM-16s, but it
is not required (see below). The DM-8 can power up to eight PM-16s using the Power-Over-Ethernet
(PoE) convention.
Each system described below first requires interfacing the console's channel inserts, direct outputs,
and/or aux sends to the IM-16 Input Module's IN connectors.
Standard PM-16 Personal Monitoring System with One DM-8
To interconnect a standard PM-16 System:
1. Connect a CAT5E cable between the IM-16's NETWORK and the DM-8's left G9 connectors.
2. Connect a CAT5E cable between the DM-8's PoE 1x Ethernet and the first PM-16's NETWORK
IN connectors.
3. Increment the DM-8's output (i.e., PoE 2x, PoE 3x, etc.), and repeat step 2 until all PM-16s are
connected.
See below if more than eight PM-16s are required.

System with One DM-8 and More than Eight PM-16s

If your system requires more than eight PM-16s and you do not have a second DM-8:
1. Follow the directions above to connect a standard PM-16 Personal Monitoring System with
eight PM-16 Mixers.
2. Connect a CAT5E cable between a NETWORK OUT on any PM-16 Mixer connected to the DM-8,
and PM-16 Mixer #9's NETWORK IN connectors.
3. Repeat step 2 for additional PM-16 Mixers.
4. Connect a power supply for each additional PM-16 Mixer that is not connected to the DM-8.
17