begin the next calibration point, otherwise, "0.0kg" will keep flickering to wait
for the stable weighing
f) Repeat the step d) and step e) above, calibrate the half capacity range point
and the Full capacity range point orderly, save the calibrated parameters
automatically and return to the weighing mode.
6.5 Switching the Unit
Press the
button to switch the unit of measurement, kg --- lb--- pcs--- kg.
6.6 Keeping Function "Hold"
Once the
key is pressed:
6.6.1 The CPU will send the weight data into RS232 socket.
6.6.2 The weight will remain on the display for 120 seconds after the
item has been removed from the scale so the weight can easily be read.
a) Place the item on the scale platform.
b) Wait for the stable weights to be displayed.
c) Press the
d) Remove the item from the scale platform. The item's weight reading will
remain on the display for 120 seconds.
e) Quit to hold function: Once an item is weighed and the hold function is
enabled; when you want to quit to hold function, press
cancel the "►" hold indicator and return the scale to weight value
6.7 Print output function
Press and hold the
weight data will output to the computer or the serial printer.
6.8 Counting Sample
a. During counting mode, remove unrelated objects on the platform, then press
button to revert to zero;
b. Press
button to switch the unit into "PCS", and the window will display
"ADD10".
ANYLOAD ES310 Postal & Shipping Scale User's Manual (V1611)
6 |
key. The "►" hold indicators will turn-on.
for 2 seconds, then the buzzer will sound, and the
the key again to