04 Wiring

04.A Connector & buttons
Strain relief
It is mandatory to place the power supply cable in the slot provided, as shown in the drawing, before powering up the DucoBox�
Illustrations and connections may vary depending on product configuration�
Incorrect connection or failure to follow the instructions may result in
damage to the connected devices�
04.B Cabling diagram
The DucoBox Silent Connect is able to communicate with Duco slave components via a wireless (RF) or wired link� Both types of
communication can be combined in one system�
Communication with non-Duco components is possible via the Switch Sensor or one of the connections on the optional Communi-
cation Print (see page 10)�
230 VAC
POWER
SUPPLY
24 VDC
Wired
24 VDC
A
B
GND
User controller
8
L2000641 Installation guide for DucoBox Silent (Revision H | 13.07.2020)
Power
230 VAC
≥ 30 cm
24 VDC
A
B
GND
Tronic vent
Blue
Switch
Duco
Contact
Wired
(n132)
DOWN
ENTER
UP
Boxsensor 1
DucoBox
Silent Connect
RF
A
B
GND
230 VAC
230 VAC
RF
230 VAC
User controller
Yellow
Red
White
Connector for
Communication Print
Fan
Boxsensor 2
HIGH
LOW
INST
RF obstacle-free zone
Do not place any obstacles causing RF
interference or other devices with an RF
connection within a radius of at least 30 cm
around the RF component� We take these to
include items such as washing machines,
tumble dryers, ironing boards, etc�
RF
Tronic vent
Max 99 Wired
Duco
Network
Tool
Antenna
+ 25 RF