Once the gauge has been positioned in the track, the Track Gauge reading can be read from
the window indicated in Figure 2.
Cant
4.2
To measure Cant, press the button located on the side of the gauge, a measurement will
appear on the screen above. Wait for a few seconds before taking a reading to ensure that the
gauge is settled. The display will turn off within a minute of pressing the button.
5.0 Maintenance
User Advice
5.1
The ABT 4550 series gauges are a piece of precision measurement equipment. Whilst it has
been designed for use in an engineering environment due care should be taken not to cause
damage to the equipment when in operation, storage or transit. Excessive trauma to the
moving parts of the gauge may invalidate the calibration and lead to possible measurement
inaccuracies.
Figure 2 - Track Gauge Reading