3onedata IAP3600S-225-2GT-PDP12 48 Snelle installatiehandleiding - Pagina 2

Blader online of download pdf Snelle installatiehandleiding voor {categorie_naam} 3onedata IAP3600S-225-2GT-PDP12 48. 3onedata IAP3600S-225-2GT-PDP12 48 4 pagina's. Industrial outdoor dual-band wi-fi6 wireless ap

11.
WAN port indicator (WAN)
12.
LAN port indicator (LAN)
13.
Bridge signal strength indicator (
14.
Breather valve
15.
Location hole
Note Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Mounting Dimension】
Unit: mm
【Pole-mounted Device Mounting】
Step 1
Use 4 M6 screws to install the clamp board as
shown in the figure below on the device backboard.
Step 2
Align the other clamp board with the hole center
line of the installed clamp board, then place the
support pipe to align the hole center of the two
clamp boards. When the two clamps are docking,
)
you can choose 15° or 90° installation angle.
Step 3
Pass the M6 long screw through the hole where the
clamp boards are docked and the support pipe, and
tighten the corresponding M6 nut.
Step 4
Install U-shaped derrick screws and derrick teeth
on the clamp board, and put the derrick with a
diameter of Ф40 mm - Ф50mm in an U-shaped slot,
as shown in the figure below.
Step 5
Adjust device position and tighten the derrick nut to
fix the position of the device on the derrick.
Installation ends.
【Pole-mounted Device Disassembling】
Step 1
Power off the device.
Step 2
Stabilize the device, unscrew the U-shaped derrick
nut and take out the U-shaped derrick screw.
Step 3
Take out the device, disassembling ends.
【Wall-mounted Device Mounting】
Step 1
Use 4 M6 screws to install the clamp board as
shown in the figure below on the device backboard.
Step 2
Align the other clamp board with the hole center
line of the installed clamp board, then place the
support pipe to align the hole center of the two
clamp boards. When the two clamps are docking,
you can choose 15° or 90° installation angle.
Step 3
Pass the M6 long screw through the hole where the
clamp boards are docked and the support pipe, and
tighten the corresponding M6 nut.
Step 4
Pass the M6 screw through the location hole of the
clamp board. The size of location hole of the clamp
board is as shown below.