Addie Water Systems IRON GENIE1 Handmatig - Pagina 18
Blader online of download pdf Handmatig voor {categorie_naam} Addie Water Systems IRON GENIE1. Addie Water Systems IRON GENIE1 19 pagina's. Chemical free iron & sulfur reduction
Piston Rod and End Plug/Seal and Spacer Replacement
1. Move the integral stainless steel bypass to the bypass position.
2. Relieve the water pressure in the Iron Genie by holding down the Extra Cycle button for 5
seconds. Once in the "BW" cycle pressure will be relieved.
3. Push extra cycle button to move control valve to "BD" cycle.
4. Push extra cycle to return the control valve to the service position (time of day on display).
5. Unplug Power Head from electrical outlet.
6. Remove the control valve back cover.
7. Remove black screw and silver washer at drive yoke on piston rod.
8. Remove two silver timer mounting screws.
9. Lift off entire Power Head assembly.
10. Remove three silver screws on stainless steel end plug retainer plate.
11. Remove end plug retainer plate.
12. Pull up on end of piston rod yoke until piston is out of valve.
13. Remove five rubber seals and four plastic spacers from valve body.
14. Replace the five rubber seals and four plastic spacers.
15. Take the piston assembly with the new piston rod and cap and push piston into valve by means
of the end plug. DO NOT pull up on piston rod.
16. Replace end plug retainer plate
17. Replace three silver screws on end plug retainer plate.
18. Twist yoke in a clockwise direction to align it with main drive gear.
19. Put Power Head on top of control valve. Be sure drive pin on main gear engages slot in drive
yoke.
20. Replace black screw and silver washer at drive yoke.
21. Replace the 2 silver timer mounting screws.
22. Return bypass to service position. Water pressure automatically builds in tank.
23. Check for leaks.
24. Plug electrical cord into outlet.
25. Set time of day and cycle the control valve through an immediate regeneration to assure proper
function.
26. Replace the Power Head back cover.