2-3
Specifications
Series
Parameter
Supply pressure
Output pressure
Input signal
Accuracy
Output air capacity
Air consumption
Ambient
S
temperature
Flame-proof : -20~60℃
Air connection
Electrical
Housing
Weight
Material (Primary)
2-4 Model Codes
1
2
3
TE □ □ □ - □ □ / □〇 □〇 □〇 □〇
1
Basic code
Series
I/P
TE
1
Converter
2
*1
7
Pressure Units
Pressure Gauge
K2
200kPa
G0
NONE
M2
0.2MPa
G1
OUT-side only
P2
30psi
SUP-side
G2
OUT-side
B2
2bar
*1 : TE200 series is only non-explosion-proof.
*2 :
Please contact us.
TE100 (with terminal box)
Accuracy ±0.5% Linearity ±0.2% Hysteresis 0.2% Repeatability 0.1%
approx. 3Nl/min (approx. 4Nl/min with Mini-set fitted)
Standard version (non-explosion-proof) : -20~80℃
Flame-proof : Ex d IIB T6 (TC13351)
approx. 1.6kg (1.8kg with a Mini-set)
integrated)
4
5
2
3
Housing
100 series
0
Standard
200 series
Flame-
5
proof
8
Input Signal
4~20mA
M1
4~12mA
M2
12~20mA
M3
M4
Special
*2
140kPa (1.4kgf/cm
20~100kPa (0.2~1kgf/cm
4~20mADC
approx. 40Nl/min
Rc1/4 (1/4NPT)
G1/2 (1/2NPT)
Non-explosion proof
Aluminum Die-casting
6
7
4
Pneumatic and
Electrical
Connections
Rc1/4・G1/2
1
S
1/4NPT・G1/2
3
1/4NPT・1/2NPT
5
9
Mini-set
Pneumatic Coupling
R1
N1
(NONE)
TE200 (no terminal box)
2
)
2
)
----
―――
approx. 1.3kg (1.5kg with a Mini-set)
integrated)
8
9
5
Ambient Temperature
-20 ~
Standard version
80℃
(non-explosion-proof)
-20 ~
Flame proof
60℃
10
Rc1/4
1/4NPT
Without Mini-set
10
6
AM
Function
M
YES
2-3