Installation Instructions

Removing the Terminal Cover

The lower cover panel and terminal cover at the bottom part of the drive are required to maintain the IP20/Chassis protection
rating. Remove the lower cover panel and terminal cover before installing the cable clamp kit. Refer to Illustration 1.1.
1.
Unfasten 4 screws (T25) and remove the lower cover panel from the drive.
2.
Unfasten 5 screws (T20) securing the terminal cover and remove the cover.
1
Lower cover panel
2
Terminal cover
3
Grommet access hole for control wiring
4
Track guide
Illustration 1.1 Terminal Cover Disassembly/Assembly
2
Cable Clamp Kit for E3h/E4h Drives
®
VLT
FC Series FC 102, FC 103, FC 202, and FC 302
5
Slotted drive bracket
6
Plastic gland plate
7
Fastener point
8
Keyhole opening
Danfoss A/S © 04/2018 All rights reserved.