Danfoss MCB 107 Installatiehandleiding
Blader online of download pdf Installatiehandleiding voor {categorie_naam} Danfoss MCB 107. Danfoss MCB 107 6 pagina's. 24 v dc supply
Installation Guide
VLT® 24 V DC Supply MCB 107
VLT® Series FC 102, FC 103, FC 202, and FC 301/FC
302
1 Scope of Delivery, Safety, and Installation
1.1 Purpose of the Manual
This installation guide describes the installation of the VLT
1.2 Purpose of the VLT® 24 V DC Supply MCB 107
®
VLT
24 V DC Supply MCB 107 option is a low voltage supply to the control card or any option card installed. This option keeps the
control section (including parameter configurations) and any installed option alive during a power failure.
External power supply
To achieve the intended functionality, an external 24 V DC supply as specified below has to be connected to the terminals of
the option.
Specifications for VLT 24 V DC Supply MCB 107
Specification
Input voltage range
Maximum input current
Average input current for FC 301/FC 302
Maximum cable length
Input capacitance load
Power-up delay
Connection terminals
•
Terminal 35: - external 24 V DC supply
•
Terminal 36: + external 24 V DC supply
Danfoss A/S © 2018.11
®
24 V DC Supply MCB 107.
N O T I C E
Value
24 V DC ±15% (maximum 37 V for 10 s)
2.2 A
0.9 A
75 m (246 ft)
<10 uF
<0.6 s
AN287957936346en-000101 / 130R0308 | 1