7.10
 BMS connection 
 
7.10.1
The EAN ESP unit is equipped with two BMS relays within the electrical console (see above figures) which should be 
connected used a 4 core electrical cable.  
7.10.2
The information relayed as well as the AOM standard cable connections are: 
POWER: use connection points 1/2 to connect to red/black cable. 
FAULT: use connection points 3/4 connect to red/white cable. 
 
7.11
 Prior to Powering the unit ON 
  
7.11.1
AOM completes a full system test prior to dispatch of the equipment, meaning that the EAN ESP unit can be plugged 
in and used immediately.  
7.12
 Powering the unit ON 
 
7.12.1
Press the switch ON‐OFF to ON. The red LED light will switch on for a few seconds, then the operating green LED will 
illuminate.  
7.12.2
A buzzing sound will indicate that high voltage is running through the electrostatic cells.  
7.12.3
The amperemeter will indicate the amperage the unit is drawing in amps: 
 
 
Min:  
Max: 
Default factory setting:  
  
 
7.12.4
AOM will dispatch the EAN ESP unit programmed on the default factory setting. Any modifications to the amperage 
of the unit should be done in consultation with your AOM Representative.  
 
21/54 Beach Street Kogarah NSW 2217     Tel Sales 1300 903 788     Service 1300 904 088 
rev 1, 22/09/2016 
 
 
 
EAN 200 
EAN 300 
0.2 amps 
0.2 amps 
0.6 amps 
0.6 amps 
0.3 amps 
0.4 amps 
 
AOM AUSTRALIA 
www.aomaus.com.au    email [email protected] 
 
 
EAN 400 
0.2 amps 
0.8 amps 
0.5 amps 
 
 
 
 
EAN 600 
0.2 amps 
0.8 amps 
0.7 amps 
 
16