⑧ Please note: The threads of the pre-pressurization cylinder need to have thread-locking adhesive applied (LOCTITE 277). After
securing it tight to the pump body the adhesive will need to solidify for at least 24 hours before reassembling the other parts. .
2.2 High-pressure and fine adjustment piston
① Refer the "Pump cleaning" section to drain out all the liquid in the pump.
② Rotate the High-pressure and fine adjustment piston handle all the way out. Use a wrench to remove part 1, part 2 and the handle as
as shown in picture 2.2.1.
Part No.
1710300261
1220116503
1653000015
1220116008
1220116009
1220116010
1653000019
1220115004
1220115044
Pre-pressurization piston
1611300112
Star shape sealing ring
1220121126
1220116505
1220115033
1220116504
Plastic liquid reservoir
1220116509
Pre-pressurization Cylinder
1611300093
1611300088
1611300078
Name
Lock screws
Screw nut
Handle
Handle spacer
Handle axle
Handle cover
Round pin
Retainer ring
Guide ring
Supporting foot
End cover
O-ring
O-ring
O-ring
Quantity
3
1
1
1
1
1
1
2
1
1
2
1
1
1
1
2
1
1
06