Danfoss living connect Installatie- en gebruikershandleiding - Pagina 14

Blader online of download pdf Installatie- en gebruikershandleiding voor {categorie_naam} Danfoss living connect. Danfoss living connect 16 pagina's. Z-wave certified electronic radiator thermostat
Ook voor Danfoss living connect: Installatie- en gebruikershandleiding (20 pagina's), Gegevensblad (8 pagina's)

Danfoss living connect Installatie- en gebruikershandleiding
User Guide

4.3 Testing the connection

1.
Press
for at least 3 seconds
until M is displayed.

5. Additional settings

5.1 Adjusting to radiator/room conditions
Press
for at least 3 seconds until M is displayed.
Press
until Pb is displayed, then press
The default setting is P2.
Use P1 if the radiator appears oversized for the room.
Use P3 if it is undersized.*
Select P1, P2 or P3 using
* The frequency of P1, P2 and P3 regulation varies to com-
pensate for radiator over/under sizing.
14 11/2013
living connect®
2.
Press
until LI is displayed.
Press
to make the connec-
tion. LI disappears when the
connection is made.
.
and exit using
.
VIIDH102
3.
If no connection can be
made, the alarm and antenna
symbols will both be flashing.
Refer to "Technical questions"
at www.living.danfoss.eu
Danfoss Heating Solutions