Danfoss ECL Comfort 210 Gebruikershandleiding - Pagina 4

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Danfoss ECL Comfort 210. Danfoss ECL Comfort 210 6 pagina's. Extended heat cut-out
Ook voor Danfoss ECL Comfort 210: Gebruikershandleiding (12 pagina's), Gebruikershandleiding (12 pagina's), Installatiehandleiding (4 pagina's), Installatiehandleiding (20 pagina's), Bedieningshandleiding (16 pagina's), Bedieningshandleiding (10 pagina's), Installatiehandleiding (7 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (20 pagina's), Installatiehandleiding (16 pagina's), Montagehandleiding (16 pagina's)

Danfoss ECL Comfort 210 Gebruikershandleiding
1.0 Symbols
ECL Comfort 210 / 310
Temperature:
Outdoor temp.
Room temp.
DHW temp.
Position indicator
Mode:
Scheduled mode
Comfort mode
Saving mode
Frost protection mode
Manual mode
Circuit:
Heating
DHW (domestic hot water)
Common controller settings
Controlled component:
Pump ON
Pump OFF
Actuator opens
Actuator closes
Alarm
Display selector
Max. and min. value
Sensor not connected / not used
Sensor connection short-circuited
Fixed comfort day (holiday)
7-23
Active infl uence
DEN-SMT/DK
4
ECA 30 / 31
ECA Remote Control Unit
Relative humidity indoor
Day off
Holiday
Relaxing (extended comfort period)
Going out (extended saving period)
VI.KT.Y1.02
Danfoss District Energy
6.0 Holiday program
There is a holiday program for each circuit
and a common holiday program for all
circuits.
Each holiday program contains one or more
schedules. It can be set to a start date and an
end date. The set period starts on the start
date at 00.00 and stops on end date at 24.00.
How to set your holiday schedule:
Action: Purpose:
Examples:
Choose 'MENU'
Confi rm
Choose the circuit selector at
the top right corner in the
display
Confi rm
Choose a circuit or 'Common
controller settings'
Confi rm
Go to 'Holiday'
Confi rm
Choose a schedule
Confi rm
Confi rm choice of mode selector
Choose mode:
• Comfort
• Comfort 7-23
7-23
• Saving
• Frost protection
Confi rm
Enter start time fi rst and then
the end time
Confi rm
Go to 'MENU'
Confi rm
Choose 'Yes' or 'No' in 'Save' .
Choose the next schedule, if
required
Danfoss District Energy
The holiday program in the 'Common
controller settings' is valid for all circuits.
The holiday program can also be set
individually in the heating or DHW circuits.
VI.KT.Y1.02
DEN-SMT/DK
9