Danfoss APP 16-22 Gebruiksaanwijzing - Pagina 6
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Danfoss APP 16-22. Danfoss APP 16-22 8 pagina's. Changing pistons
Ook voor Danfoss APP 16-22: Instructies voor demontage en montage (18 pagina's)
Instruction
6
Changing pistons APP 11-13 and APP 16-22
4.
Replace the O-ring on the mounting flange.
6.
Mount the 3 screws as shown below. Turn
each screw a couple of rounds at the time,
to ensure the swash plate is pulled as
straight forward as possible.
Note : Be careful not to squeeze/damage
the O-ring.
8.
Connect the pump to the rest of the
system.
10.
Follow the start-up procedure, see
instruction 180R9223.
180R9227 / 521B1194 / DKCFN.PI.013.O1.02 / 03.2012
5.
Carefully insert the swash plate into the
housing.
7.
Insert the remaining screws and cross
tighten them to a torque of 30 Nm
+/- 3 Nm.
9.
Bleed the pump.