Danfoss APP 21-26 Servicehandleiding - Pagina 8

Blader online of download pdf Servicehandleiding voor {categorie_naam} Danfoss APP 21-26. Danfoss APP 21-26 20 pagina's. Disassembling and assembling

Danfoss APP 21-26 Servicehandleiding
Disassembling and Assembling, APP 21-43
Service guide |
8 | 180R9121 | 521B1018 | DKCFN.PI.013.A6.02
16. Retainer guide, retainer ball and
retainer plate must be mounted as
indicated in below picture.
18. Place retainer plate in cylinder barrel.
Note: If pistons are replaced, place new
pistons in clean filtered water for a
couple of minutes. Exercise piston shoes
to make them "run" smoother.
21. Remember to place the guide pin in the
housing.
22. Place three bolts in mounting flange.
Turn each bolt one round at a time to
ensure mounting flange is mounted as
straight downwards as possible. Be careful
not to squeeze O-ring.
17. Ensure that retainer plate is oriented
correctly, i.e. with its slant surfaces
pointing downwards.
19. Place pistons in retainer plate and
cylinder barrel.
When pistons are placed, tilt retainer
plate for easier placement of swash plate.
If swash plate has been disassembled from
mounting flange, see page 10 for assembly
of swash plate.
20. Lubricate piston shoes and swash plate
with clean filtered water. Remember to
place the pins in housing.
Note: Screws for lifting eye are
shorter than the rest.
23. Screw in the rest of the bolts and cross
tighten all screws to a torque according to
exploded view.
© Danfoss | DCS (im) | 2017.06