Danfoss APP series Instructies voor demontage en montage - Pagina 3

Blader online of download pdf Instructies voor demontage en montage voor {categorie_naam} Danfoss APP series. Danfoss APP series 12 pagina's. Disassembling and assembling
Ook voor Danfoss APP series: Servicehandleiding (12 pagina's), Servicehandleiding (12 pagina's), Instructie (10 pagina's)

Danfoss APP series Instructies voor demontage en montage
Service guide | Disassembling and Assembling, APP 1.5-3.5
1. Disassembling and
assembling the pump
© Danfoss | DCS (im) | 2017.08
1. Unscrew the 4 mounting screws and
remove seal SAE flange.
Do not yet unscrew the 2 lower screws.
3. Unscrew the 2 lower screws.
5. Remove the housing.
2. Wet the shaft and shaft seal with clean
(filtered) soap water. Gently lever the shaft
seal assembly free using 2 screwdrivers.
4. Carefully turn the whole pump over so
that the shaft is facing down. Support the
pump in a suitable hollow base so that the
pump is not supported by the shaft.
APP 1.5-2.5
APP 3.0-3.5
6. Remove the pistons, retaining plate,
retaining ball, spring guide, and spring
from the cylinder barrel.
180R9091| DKCFN.PI.013.EF5.02 | 521B0741| 3