14 |
©
Danfoss | August 2021
Service and repair of D1P pump
In case a service or repair intervention on the pump is required, it must be performed according to the
information shown in below mentioned Repair Instructions.
The Repair Instruction includes the spare part list and information about how dismantling and
assembling of the pump is done properly.
Only Authorized Service Centers may perform repairs specified in the Repair Instructions.
•
D1 High Power Open Circuit Pumps Repair Instructions: Literature number AX195286485156.
Safety precautions
Always consider safety precautions before beginning a service procedure. Protect yourself and others
from injury. Take the following general precautions whenever servicing a hydraulic system.
Tools
W
Warning
It is compulsory to use anti sparking safety tools in case the service/repair activity has to be performed in
explosive hazardous atmosphere.
Unintended machine movement
W
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
To protect against unintended movement, secure the machine or disable/disconnect the mechanism
while servicing. Follow the manufacturers instructions for securing the machine.
Personal safety
W
Warning
Protect yourself from injury. Use proper safety equipment, including safety glasses, at all times.
Flammable cleaning solvents
W
Warning
Some cleaning solvents are flammable. To avoid possible fire, do not use cleaning solvents in an area
where a source of ignition may be present.
Fluid under pressure
W
Warning
Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin causing serious
injury and/or infection. This fluid may also be hot enough to cause burns. Use caution when dealing with
hydraulic fluid under pressure. Relieve pressure in the system before removing hoses, fittings, gauges, or
components. Never use your hand or any other body part to check for leaks in a pressurized line. Seek
medical attention immediately if you are cut by hydraulic fluid.