Duo-Therm 57915.521 Handleiding voor installatie en gebruik - Pagina 12

Blader online of download pdf Handleiding voor installatie en gebruik voor {categorie_naam} Duo-Therm 57915.521. Duo-Therm 57915.521 17 pagina's. Roof top air conditioner/heat pump
Ook voor Duo-Therm 57915.521: Handleiding voor installatie-instructies (17 pagina's)

Duo-Therm 57915.521 Handleiding voor installatie en gebruik
Installing unit with 3105007.XXX or 3105935.XXX
Return Air Cover.
A. INSTALLATION OF CEILING TEMPLATE
1.
Check gasket alignment of the air conditioner over
the roof opening and adjust if necessary. Unit may
be moved from below by slightly lifting and sliding.
See FIG. 11A.
2.
Remove return air cover and ceiling template from
the 3105007.XXX or 3105935.XXX kit carton.
FIG.
10A
Ceiling Template
Return Air
Grill
3.
Locate 1/4 " unit mounting bolts in the parts pack-
age.
4.
Hold the ceiling template up to the 14-1/4" x 14-1/
4" (±1/8") opening. Be sure the large plate faces
the rear of the RV.
FIG. 11A
Center Unit From Below
4 Wire Thermostat
Cable
Installing unit with 3105007.XXX or 3105935.XXX
Return Air Cover, continued on page 12, column A.

10. INSTALLATION OF AIR CONDITIONER

Divider Plate
Return Air
Cover
Gasket
AC Power
Supply
Pull Conduit Down
INSTALLATION INSTRUCTIONS DUCTED BI-METAL
Installing unit with 3308120.XXX Genesis Air Filtra-
tion System.
Note: A 12VDC power source is required for this installa-
tion. See Section 5. B. Paragraph 6
A. INSTALLATION OF FOAM DIVIDER
1. Locate the foam divider and insert it corner to cor-
ner in the 14-1/4" x 14-1/4" (±1/8") opening with
the adhesive tape up (Do not remove paper to ex-
pose adhesive). The foam divider should be level
with the ceiling (±1/4"). Tear off the excess at the
FIG. 10B
Base Pan
Upside
Down
Foam
Divider
Place Foam Divider in
(14-1/4" x 14-1/4" (±1/8")
Ceiling Opening against
Base Pan Bottom
pre-cut perforations in divider. See FIG. 10B.
2. Peel the paper off of the foam divider and stick it in
place on the center of the rear edge of the return air
FIG. 11B
Adhesive
Peel Off Paper - Center Divider - Stick To
Rear Flange On Ceiling Template
opening on the ceiling template See FIG. 11B.
B. INSTALL CEILING TEMPLATE
1. Position the electrical control box towards the front
of the opening with all of the system control wires
connected to the control box. Place the ceiling tem-
plate up to the return air opening in the ceiling. See
FIG. 12B.
Wires Connected To
Control Box
FIG. 12B
Vehicle
Front
Installing unit with 3308120.XXX Genesis Air Filtration
System, continued on page 13, column B.
12
Do Not Peel Tape Off
Adhesive
Ceiling
Foam Divider Ceiling
(±1/4")
Level
Tear Off
Excess
Foam Divider
Control
Box
Base
Pan