3.2.6 Calibration reminder function

With this feature enabled, every six-weeks CAL and
flash on the display as a reminder to check the pH electrode
calibration . For a period of 10 seconds you will hear a beep every 2 seconds . This will be repeated every hour .
If you prefer not to carry out a calibration, the memory display clears after activating any button and reappears in
another 6 weeks .
In order to calibrate the pH electrode, enter programming mode by pressing the
button and follow item 5 .2 .4 of
the instructions .
To disable of the calibration memory function, continue to scroll through the menu items and set the function to
.

3.3 Timer programming

3.3.1 Setting the timer control mode

As an alternative to temperature regulation, the second slot can be used to control external devices via a timer switch
with a one-second control interval . Selection is between
(external device at slot 2 is permanently activated),
(automatic modus) and
(interval mode) .
3.3.2 Programme turn-on and turn-off times
If Automatic Mode is selected up to 8 turn-on/turn-off times can be programmed . (The Dupla pH-Control Pro has
an automatic sorting function which will re-arrange the time periods into the correct sequential order when exiting
programming mode .)
3.3.3 Programme interval control
If the Interval mode is selected external devices are switched on for a minimum of 1 second (maximum 23 hrs ., 59
min . and 59 sec .) and switched off for a minimum of 30 minutes (maximum 96 hrs . and 59 min .) .

3.4 Manual activation/deactivation

Both slots can be turned on and off manually by combination of buttons to be pressed .

3.5 Display light

Factory presetting is an automatic adaptation of the display light . After pressing any button the display light is
switched on . When no button has been pressed for 120 seconds, the display light is automatically dimmed down . It is
possible to change from automatic light dimming to full illumination of the display .