Dangerous Music CONVERT-AD Plus Gebruikershandleiding - Pagina 10
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Dangerous Music CONVERT-AD Plus. Dangerous Music CONVERT-AD Plus 19 pagina's.
| DANGEROUS MUSIC
6
Benefit: For use with devices that have a SPDIF optical input.
12. SPDIF COAX OUTPUT
[REAR PANEL WORD CLOCK INPUT & OUTPUT CONNECTORS PICTURED ABOVE]
Feature: Optical SPDIF COAX output.
Benefit: Another option for digital output, more common on modern interfaces than AES format.
,
Tip:
Use a high quality, 75 ohm RCA - RCA cable (like those made by Jumperz Audio Cables and Mogami)
13. WORD CLOCK IN & OUT
[REAR PANEL OPTICAL SPDIF INPUT CONNECTOR PICTURED ABOVE]
Feature: 3 Modes: Normal, External and Master.
Benefit: Normal: Selecting this button press will make the Convert-AD+ sync to any incoming clock via any of the digital
sources.
External: Deselecting this button will make the Convert-AD+ slave to an external word clock source. For example, if
utilizing a master studio clock, this would distribute WC to the Convert-2.
Master: Depress the button for 5 seconds. The LED will blink. Now the Convert-AD+ is the master studio clock and
other digital sources should slave to it. (Audition the difference.)
Note:
When in Master clock mode, the sample rate must be manually selected and the destination devices must be set to the
identical parameters (i.e. all units at 192kHz).
,
Tip:
Try utilizing the Convert-AD+ as the master clock. Our high profile beta testers found it "remarkably revealing &
detailed" and "...this is the best sounding clock auditioned to date- and we've tried everything. "
14. USB OUTPUT