Breathing Air Requirements for Encapsulating
Design Garments
Encapsulating garments are designed to completely cover
the wearer, including all respiratory equipment (except
for external air supply lines, if applicable). Encapsulating
garments require that fresh breathing air be supplied to the
wearer at all times.
CAUTION: YOU MUST USE AN OPEN CIRCUIT SELF-
CONTAINED BREATHING APPARATUS OR AIR-LINE SUPPLIED
RESPIRATOR WITH ALL ENCAPSULATING GARMENTS.
Other Personal Protective Equipment
To help protect you while wearing a Tychem
use of other personal protective equipment (PPE) items
is often required based on the hazard assessment. PPE
selection must be conducted by a trained and experienced
safety professional. Additional protective equipment may be
required to deal with hazards such as, but not limited to, the
following:
•
Flammable or Explosive Environment
•
Extreme Heat (Heat Stress)
•
Extreme Cold (Hypothermia)
•
Physical Hazards (Sharps, Puncture, Rough Surfaces,
Falling Debris)
•
Slipping Hazards
•
Visibility Requirements
•
Fall Protection
•
Contamination Avoidance
Respirators
Tychem
encapsulating suits must be worn with a full
®
face, supplied air respirator. The user must be trained and
physically fit to use a respirator. The performance of your
respirator must be verified with a performance based fit
test. Failure to properly select, test, use and maintain your
respirator can result in serious injury or death. The selection
of the appropriate respirator is the responsibility of the
safety professional or industrial hygienist.
4
Tychem
Encapsulated Level A and Encapsulated Level B Suits
™
®
garment, the
®
The full face, supplied air respirator worn with
encapsulating Level A or Level B Tychem
include:
•
An open circuit, self-contained breathing apparatus
(SCBA) certified as compliant with NFPA 1981, "Standard
on Open-Circuit Self-Contained Breathing Apparatus for
Fire Service"
or
•
An external, breathing air-quality, air-line system with
garment pass-through and escape bottle.
Do not wear a closed-circuit (rebreather-type) SCBA with
Tychem
encapsulating Level A or encapsulating Level B
®
garments. Do not wear an air-purifying respirator (APR) or
a powered, air-purifying respirator (PAPR) inside a Tychem
encapsulating Level A or encapsulating Level B suit.
Footwear
You must wear separate, user-supplied, protective footwear.
The socks attached to encapsulated Level A and Level B
Tychem
garments must be worn inside protective footwear.
®
Failure to wear appropriate user supplied footwear will
damage the attached sock. It is the user's responsibility
to verify that appropriate footwear has been selected and
used based on a hazard assessment. For NFPA certified
Tychem
encapsulated ensembles, refer to the appropriate
®
Technical Data Package for a list of approved footwear for
use with those ensembles.
Gloves
All Tychem
Level A suits have attached chemical resistant
®
glove systems. Tychem
Level B encapsulating suits may or
®
may not have attached glove systems. For NFPA certified
suits, refer to the Technical Data Package for glove system
information. For non-certified encapsulated Level A or
Level B suits contact DuPont for information regarding
glove system details for specific suit models. It is the user's
responsibility to verify that appropriate gloves have been
selected and used based on a hazard assessment.
garments must
®
®