DANLERS DUSW Installatie-opmerkingen - Pagina 2
Blader online of download pdf Installatie-opmerkingen voor {categorie_naam} DANLERS DUSW. DANLERS DUSW 2 pagina's. Dusk switch
Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a qualified electrician.
2. The switch should be sited such that it can receive more daylight
than artificial light. Ensure that any artificial light is not too close to
the switch or shining directly into it.
3. The switch must be mounted via the four pre-formed holes only,
no additional holes should be drilled through the enclosure. The
spindles must point down, with room below to adjust them.
4. The cable enters from above, either through a 20mm threaded
conduit or via the cable gland provided, in which case the cable
must be circular with a diameter of between 6 and 12mm.
5. Make sure the power is isolated from the circuit.
6. The detector should be connected as shown in diagram A
L
Live in
N
Neutral in
SL
Switched Line out.
7. Once the wiring has been completed and verified, switch on the
supply and test the operation.
Time and Lux set-up
The time for which the lamp will stay on for can be adjusted from
approximately 2 to 16 hours as shown in diagram B.
The LUX is best set up when the ambient light is at approximately
the level at which you wish the lights to come on at. With the external
LUX adjuster set fully clockwise to '-' (Dark) wait for the DUSW switch
to turn off. Rotate the LUX adjuster slowly anticlockwise to '+' (Dark
to Light), at each new position wait about 5 seconds for the DUSW to
react to the change.
A: Wiring diagram
DUSW
L
optional manual
wall switch for
overriding off
230 VAC
N
B: Time and Lux adjustment
- LUX +
On
On
when
when
Dark
Light
SL
N
load
+ TIME -
16
hours
hours
2