EXTENDED MENU 2
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
To enable the functions listed in Extended Menu 2, proceed as
follows: open Extended Menu 1 (as instructed in the respective
section), then press and hold the SET key for 5 seconds, the T.
PAUSA LED and RIT. ANTE LED will flash simultaneously,
accordingly, you have 30 seconds to select the functions of
Extended Menu 2 using the SEL and SET buttons. After
another 30 seconds, the control unit returns to the main menu.
----------------------
EXTENDED MENU 2
Reference LED
LED Off
A) AUT / P-P
Follow Me = OFF
B) CODE
PreFlash. and Cort. L=OFF PreFlash. or Cort. L. =ON
C) CODE PED.
Pause Lamp. = OFF
D) INB.CMD.AP SOFT START = OFF
E) T. MOT.
El. Gate CMD PED = OFF
F) T.MOT.PED.
PUL=PUL - PED=PED
G) T. PAUSA
Flashing beacon ON/OFF simultaneous
H) RIT. ANTE
Flashing beacon ON/OFF in simultaneous
A) AUT/P-P ( Follow Me ) :
It is possible to set the "Follow Me" function on the control unit:
this function can only be programmed if a Pause Time has
already been programmed, and it is used to shorten the Pause
time to 5 sec after the photocell DS1 disengages, i.e. the gate
closes 5 seconds after the user has passed through.
wish to enable the function, proceed as follows: make sure that
you have enabled Extended Menu 2 (T. PAUSA LED and RIT.
ANTE LED start flashing simultaneously), with the SEL key
position on the flashing of
key, the AUT/P-P LED will simultaneously switch on steadily
and programming is completed. Repeat the procedure to
restore the previous configuration.
B) CODE ( Pre-flashing / Courtesy Light ) :
The control unit is supplied by the manufacturer with Pre-
flashing and Courtesy Light functions disabled. If you wish to
enable the Pre-flashing function, proceed as follows: make sure
that you have enabled Extended Menu 2 (T. PAUSA LED and
RIT. ANTE LED start flashing simultaneously), with the SEL key
position on the flashing of CODE LED then press the SET key,
the CODE LED will simultaneously switch on permanently and
the programming is completed. If you wish to enable the
Courtesy Light, repeat the operation described above, pressing
the SEL button twice instead of once (the CODE LED will flash
rapidly).
Repeat the operation to restore the initial configuration.
Pre-flashing** function The flashing beacon 230 Vac is
always activated 3 seconds before the automation starts any
type of motion.
Courtesy Light Function:
output will be activated for 3 minutes, each time that an
opening command is given.
C) CODE PED ( Flashing beacon function ) :
The control unit is supplied by the manufacturer with the
flashing beacon function during the enabled Pause Time. If you
wish to disable the function, proceed as follows: make sure that
you have enabled Extended Menu 2 (T. PAUSA LED and RIT.
ANTE LED start flashing simultaneously), with the SEL key
position on the flashing of PED CODE LED then press the SET
key, the PED CODE LED will simultaneously switch on
permanently and programming is completed. Repeat the
procedure to restore the previous configuration.
D) INB. CMD. AP. LED ( SOFT START ) :
The control unit is supplied by the manufacturer with the Soft
Start function disabled. If you wish to enable the function,
Pagina 5 di 6
-----------------
LED On
Follow Me = ON
Pause Lamp. = ON
SOFT START = ON
El. Gate CMD PED = ON
PUL=AP - PED=CH
AUT/ P-P LED then press the SET
The Flashing beacon 230 Vac
proceed as follows: make sure that you have enabled Extended
Menu 2 (T. PAUSA LED and RIT. ANTE LED start flashing
simultaneously), with the SEL key position on the flashing of
INB.CMD.AP LED then press the SET key, the INB.CMD.AP
LED will simultaneously stay on steadily and programming is
completed. Accordingly, every time the gate starts motion the
control unit will control motor start-up, increasing the power
gradually from minimum to maximum in the first two seconds of
operation. Repeat the procedure to restore the previous
configuration.
E) T. MOT. (Electric Lock activation CMD PED.) :
The control unit is supplied by the manufacturer with the
activation of the electric lock through the disabled Pedestrian
command. If you wish to enable the function, proceed as
follows: make sure that you have enabled Extended Menu 2 (T.
PAUSA
LED
simultaneously), with the SEL key position on the flashing of
T.MOT. LED then press the SET key, the T.MOT. LED will
simultaneously switch stay on steady and programming is
completed. The activation of the electric lock function through
the Pedestrian command, is used when you have, for example,
a sliding gate with a door next to the Pedestrian passage.
Accordingly, the gate can be opened with the PUL commands
as well as from the Pedestrian door using the electric lock with
the PED. commands.
restore the previous configuration.
If you
F) T. MOT. PED ( PUL and PED command functions ) :
The control unit is factory supplied with PUL control input
operation for the connection of a cyclical primary control button
(NA) and a PED input for the connection of a cyclical
Pedestrian command button (NA). If you wish to select another
mode of function of the PUL and PED inputs, proceed as
follows: make sure that you have enabled Extended Menu 2 (T.
PAUSA
LED
simultaneously), by using the SEL key select the flashing T.
MOT PED. LED and press the SET button: T. MOT. PED.
LED remains steadily lit and programming is complete.
Accordingly, the PUL input makes it possible to connect a
button (NA) for the Opening phase only, and the PED input for
connection to a button (NA) for the Closing phase only. Repeat
the procedure if you wish to restore the previous configuration.
EXTENDED MENU 3
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
To enable power programming
carried out by the control unit,
Extended Menu 2 (as instructed in the respective section), then
press and hold the SET key for 5 seconds, after which the T.
PAUSA LED and RIT. ANTE LED will start flashing alternately
and then simultaneous, in this way there will be 30 seconds to
select the desired deceleration using the SEL and SET keys,
then, after a further 30 seconds, the control unit returns to the
main menu.
----------------------
Level
1
2
3
4
AUT / P-P - CODE - CODE PED. - INB. CMD. AP. LED
AUT / P-P - CODE - CODE PED. – INB. CMD. AP - T. MOT.
5
6
AUT / P-P - CODE -CODE PED. - INB. CMD. AP - T. MOT. - T.MOT.PED.
and
RIT.
ANTE
LED
Repeat the procedure if you wish to
and
RIT.
ANTE
LED
functions for deceleration
proceed as follows: open
EXTENDED MENU 3
Leds On
AUT / P-P
AUT / P-P - CODE
AUT / P-P – CODE – CODE PED.
Rev. 1.1 del 12-03-2015
start
flashing
start
flashing
-----------------