C
ONTROLS
The heater is fitted with a built-in thermostat to control the temperature level to which
the room is heated. The thermostat adjustment knob is located on the right hand end and
is numbered. Rotate the knob clockwise to a higher number to raise the room temperature.
Once set it is unlikely to require being touched again.
To set the heater to the Frost Watch mode, turn the thermostat control
knob fully anti-clockwise until the frost symbol aligns with mark.
The switches on the side panel of the heater operate to give:
fan only or 2 kW. See Fig 1.
C
M
S
ONNECTION TO THE
AIN
UPPLY
Electrical installation should be carried out by a competent installer, preferably
registered with NICEIC (National Inspection Council for Electrical Installation
Contracting) in accordance with the 16 edition of the IEE Wiring Regulations, (BS.7671:
1992), and any relevant Local Authority Bye-Laws.
This heater is fitted with a 3-core mains supply cable and should be permanently
connected to the electricity supply via a double pole switch having 3mm gap on each pole.
A switched Fused Connection unit to BS.1363. Part 4 is a recommended mains supply
connection accessory to ensure compliance with safety requirements applicable to fixed-
wiring installation.
T
O
C
-
HERMAL
PERATED
UT
OUT
The appliance is fitted with an
Electronic Safety Control (ES). This is
a safety device which switches the
heater off if, for any reason, the
appliance overheats. The ES control
must be re-set manually. This must be
done by a competent electrician. The
re-set button is on the ES control
located in the center of the heating
element inside the heater.
For
assistance with this, please ring our
helpline (see back page of document).
The heater carries a 'Do Not Cover'
label to warn the user that if the
appliance is covered, there is a risk of
overheating.
W
M
ALL
The heater must not be located immediately below a fixed socket outlet.
The Wall Mounting brackets are packed separately in the carton. Fit the top mounting
brackets to the wall at the height and centres shown in the diagram. Withdraw the two
feet-securing screws from the base of the heater and use these screws to secure the right-
angled brackets to the base of the rear panel of the heater in the correct holes. These are
the holes in the two protruding lugs.
Mount your appliance onto the top brackets via the two slots in the rear panel. Secure
the bottom bracket to the wall as shown.
IMPORTANT – ALWAYS RETAIN YOUR USER INSTRUCTIONS FOR FUTURE REFERENCE.
S
AFETY
This equipment has been designed and manufactured to the highest international
standards, but, like all electrical appliances which are operated by mains voltage, care
must be taken if you are to obtain the best results and safety is to be assured.
NOTE: The appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge
unless they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance
Do NOT site the appliance into a corner when in use.
Do NOT use this heater in the immediate surroundings of a bath, a shower or a
swimming pool.
Do NOT handle the appliance with wet hands.
Do NOT use the appliance in workshops or rooms where excessive dust is
generated or present.
Ensure that nothing is pushed into any aperture of this appliance.
Do NOT touch outlet grille when the appliance is in use.
Do NOT cover or restrict any aperture of the appliance when in use.
Do NOT use the appliance if damaged.
Do NOT leave the appliance unattended where young children are present.
This appliance meets the requirements of EU Directive 89/336 for EMC.
62001097 Iss 02
OUNTING
WARNING – THIS APPLIANCE MUST BE EARTHED