1.1.3. FireSpy 1600,3200
1.1.3.1. FireSpy Front
IEEE1394b Connectors (3x)
With these connectors the FireSpy 1600 can be connected to the IEEE1394b buses to be analyzed. All
connectors are beta ports. This means that they only can be connected to a 1394b (beta) port S800 or
S1600.
Active led
Off: Power is off
Red: Power on, PCIe Link not active
Red and Green: Power on, PCIe Link active
Green: Power on, Link operational
Generator LED
Reserved for future use.
Record LED
Off: Recorder not active
Green: Recorder is active
Red: Recorder buffer full. This means the host can not keep up with writing the data to hard driver during
recording. Please try pointing the temporary recording file to a faster hard driver (SSD).
Trigger LED
Off: No trigger occurred
Green: A trigger occurred
Manual Trigger
Pressing this button during Recording marks a trigger point in the current recording
Holding this button during power-up loads the factory fallback firmware into the FPGA. Only the
programmer is active, used for recovering from a faulty firmware upgrade.
External trigger
Using this connector, the FireSpy can be triggered with an external electrical signal when recording is in
progress and the Recorder is not yet triggered.
The FireSpy is triggered when it detects a positive pulse .....