• Do routine maintenance Inspect gaskets seals, plastic parts, filters, switches and replace
those which have begun to leak or are damaged.
• Using a machine with a damaged power cord could result in an electrocution. Check the cord
looking for cut, cracks or aging signs and replace it if it's necessary.
• Only an authorized service centre can replace power cord of the appliance.
• If extension cord are used, ensure that the cable rating is suitable for use with the
equipment. Keep dry at all times. Avoid contact with conductive surfaces.
• Don t let children clean the appliance if they are not under supervision of an adult
• Only an authorized service centre can do reparation or maintenance of the appliance. Use
only original spare parts.
• To keep the appliance fully functional it is necessary to clean polyester filter shaking it after
every use and replace filtering bag if it's full.
• Clean every part of the appliance after each use: empty the tank, shake the filters, replace
filtering bag if it's full and clean the machine with a damp cloth before storing the vacuum cleaner.
• WARNING: in case of foam or liquid leak switch off the appliance immediately.
• WARNING: in case overturning, lift the appliance in the upright position before switching the
motors off.
WARNING: The additional socket must be used only with the appliance in dry mode (while
vacuuming dusts). Failure to comply with these rules can lead to fires and dangers even
lethal to the user.
• Don't pick up water from sink or tub. Do not use cleaner as a pump to clean out clogged drains,
sinks, or other plumbing fixtures. The vacuum cleaner is intended for vacuuming air and water
mixtures.
• Do not use or pick up aggressive soaps, they could damage the appliance.
WARNING: The float valve has the function to stop the vacuuming when the tank is full of
liquids or in case of overturning; carry out cleaning routine checking that there are no
damages and change it if it's necessary.
• WARNING: Do not use outdoors or in a cold environment.
• Do not run the pump dry.
• After operating, when the pump is off, press the tap lever to relieve the machine from pressure.
• After each use, empty the tank and fill it with 1/2 liter of clean water. Let the machine
run in order to thoroughly rinse the pump. Also thoroughly rinse the flexible hose.
• To correctly use soaps and detergents, follow the instructions reported on the products, including
the use of personal protective equipment (if required).
NOISE
Values measured according to EN 60704-1 (1997) I EN 60704-2-1 (2001) ISO 3744 standards.