WARNING: INSTALL ONLY THE TERMINATIONS OUTLINED IN THESE INSTRUCTIONS AND
MANUFACTURED BY CONTEMPO. A SERIOUS FIRE HAZARD COULD EXIST IF USING NON-LISTED
TERMINATION. THIS CHIMNEY SYSTEM IS NOT INTENDED FOR HORIZONTAL TERMINATION.
GAS LOG CONVERSION
See pre-installation sheet.
This provision for installation of gas pipe is intended for connection to a decorative gas appliance that
incorporates an automatic shutoff device and complies with the Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces, ANSI Z21.60. The decorative gas appliance must be installed in accordance
with the National Fuel Gas Code, ANSI A223.1
WARNING: WHEN USING THE DECORATIVE GAS APPLIANCE, THE FIREPLACE DAMPER MAY HAVE
TO BE PERMANENTLY REMOVED CHECK YOUR LOCAL CITY CODES.
WHEN THIS UNIT HAS BEEN CONVERTED TO GAS THE GLASS DOOR AND THE ANDIRON
GRATE ARE NOT REQUIRED
FOLLOW THE INSTALLATION MANUAL PROVIDED BY THE GAS LOG MANUFACTURER.
This fireplace was tested to UL127 standards for zero clearance fireplaces, as applicable to gas log
installation 54.3.2s.
USE ONLY VENTED GAS APPLIANCES THAT 1) HAVE AN AUTOMATIC SHUT-OFF DEVICE, AND 2)
COMPLY WITH STANDARDS FOR DECORATIVE GAS APPLICANCES FOR INSTALLATION IN VENTED
FIREPLACES, ANSI Z21.60-1996/CGA 2.26-M96, OR LOS ANGELES RGA 2-72 OR AGA DRAFT
REQUIREMENTS FOR GAS-FIRED LOGLIGHTER FOR WOOD BURNING FIREPLACES, DRAFT NO. 4
DATED AUGUST 1993. THE GAS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH THE
NATIONAL FUEL GAS CODE, ANSI Z223.1 (NFPA 54)
WARNING: THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO
REDUCE THE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THIS
FIREPLACE.
NOTE: The data plate is located on the front top inside of the firebox.