Darfon G320 Gebruikershandleiding - Pagina 12

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Darfon G320. Darfon G320 14 pagina's. Micro inverter

G 3 2 0
M i c r o
I n v e r t e r
Step2. Verify that the AC voltages at the electrical utility connection and at the
junction box for each circuit are within the appropriate range.
Wire Connection
L1 to L2
L1 to neutral
L2 to neutral
Step3. Verify the PV module DC voltage is within the allowable voltage and
wattage range shown in the Technical Specifications section.
Verify the DC leads are connected correctly between the micro inverter and the
PV module.
If the micro inverter's COMM Status LED is off, then follow these steps:
Step1. Verify that the Power Status of the micro inverter is functioning properly.
Step2. Verify that the data logger is uploading data to the monitoring software.
If the problem persists, contact the Technical Support at [email protected].
Manuals-non monitoring system(for BD use)-08023
G 3 2 0 + 1 T c a b l e U s e r
240V (Single Phase)
211 to 264VAC
106 to 132VAC
106 to 132VAC
TECHNICAL SPECIFICATIONS

Micro Inverter

INPUT FROM PV (DC)
Number of Panels per Inverter
Nominal Power (STC) of Each Panel
Recommended STC Panel Power
Maximum Panel Voltage
Operating Voltage Range
MPPT Voltage Range
Minimum Start Voltage
Maximum Current per Panel
OUTPUT DATA (AC)
Nominal Continuous Power Rating
Nominal Frequency (Range)*
Power factor
Total Harmonic Distortion
Nominal Voltage / Range
Nominal Output Current
Max. Units per 20A Circuit
EFFICIENCY
Peak Efficiency
CEC Weighted Efficiency
Nominal Static MPPT Efficiency
MECHANICAL & ELECTRICAL
3-Phase Configuration
Night time power consumption
Ambient Operating Temp. Range
Internal Operating Temp. Range
Weather-Proof Rating
Dimensions LxWxH
Weight
COMPLIANCE & COMMUNICATION
UL, FCC, IEEE Compliance
Communication
* Range programmable at the factory per customer request or local regulation
© 2 0 1 6 D a r f o n E l e c t r o n i c s C o r p .
U s e r
M a n u a l
G320
One
320 W
200~350 W
60 V
22~60 V
24~45 V
24 V
12 A
300 W
60 (57~63) Hz
> 0.99
< 2%
240 /
211~264V
1.25 A
12
96.5%
96.0%
>99.5%
WYE link
< 20 mW
-40 to 65 °C
-40 to 85 °C
NEMA 6 or IP67
268 x 195 x 34 mm
1.3 kg
UL 1741, FCC Part 15, Class B, IEEE 1547
PLC