4B M100 Bedieningshandleiding - Pagina 7
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} 4B M100. 4B M100 12 pagina's. Stopswitch stopped motion monitor
The M100 Stopswitch should be wired as indicated by the connection diagram.
The M100 Stopswitch must be wired through a load/resistor (see standard wiring diagram) and not directly
to supply voltage. The supply polarity is not important and the load can be connected in either wire.
Do not wire the M100 Stopswitch to a motor starting coil.
It is not recommended to wire the M100 Stopswitch in series with other sensors.
The cable on the M100 Stopswitch can be extended to virtually any length in ordinary 2 wire cable.
Two locknuts are provided to mount the M100 Stopswitch in position. Mount securely to withstand vibration.
Ensure that the unit and target are adequately guarded (refer to page 8).
DIMENSIONS
INSTALLATION
WARNING
Rotating parts can
crush, cut and entangle.
Do NOT operate with
guard removed.
Lockout power before
removing guard or
servicing.
PAGE 7