FLAMEPROOF Exd TRANSMITTERS ACCORDING TO
10.1.
CERTIFICATES JSHP 22 ATEX 0051X
10.2.
Standards used for assessment
The transmitters are manufactured in compliance with the following standards:
EN IEC 60079-0:2018; (IEC 60079-0:2017 ed. 7.0),
EN 60079-11:2012; (IEC 60079-11:2011 ed. 6.0.),
EN 60079-1:2014; (IEC 60079-1:2014 ed. 7.0),
EN 60079-31:2014; (IEC 60079-31:2013 ed. 2.0).
10.3.
Transmitters explosion-proofing designations (Exd and Ext)
according to certificate JSHP 22 ATEX 0051X
The following ATEX markings apply only to flameproof safe transmitters Exd and Ext:
ATEX:
II 1/2G Ex db ia IIC T5/T4/T3 Ga/Gb
II 1D Ex ia ta IIIC T100ºC/T135ºC/ T155ºC Da
JSHP 22 ATEX 0051X
11.
PERMISSIBLE PARAMETERS OF Exd and Ext
TRANSMITTERS
11.1.
Ambient temperature range and temperature classes
Table 3. Temperature classes and maximum surface temperature depending on ambient and
fluid temperature.
Operating temperature range
Ambient
temperature
-40ºC ≤ T
Revision 01.A.001/2022.09
Process
temperature
90ºC
≤ 75ºC
125ºC
a
150ºC
Temperature class and
maximum surface temperature
T5/T100ºC
T4/T135ºC
T3/T155ºC
EN.IX.APM.2
13