DEPLOYMENT AND INSTALLATION
TS-100 aspirated radiation shields come partially pre-assembled and have few parts, facilitating easy
transport, deployment, and maintenance.
Avoid placing the shield near buildings, paved surfaces, or any other locations which may create a micro-
environment significantly different than ambient environment. The World Meteorological Organization
(WMO) recommends a mounting height of 1.25 to 2 meters above ground. Air temperature typically
decreases with increasing height above the ground surface.
lead wires.
The precision thermistor comes fixed inside a
adapter
installed, insert the
matches the shield's outer contour and will not come out when pulled. Look through the opening at the
bottom of the shield to verify that the thermistor tip is located concentrically in the middle of the
airstream. If it is not, remove the
sensor port adapter
sensor port
into the
(shown on next page) and rotate the adapter until it
adapter
and adjust the thermistor tip accordingly.
(shown on next page). If not already
The shield is designed to
hang from a standard IPS
horizontal pipe ranging from
1¼ inch (32 mm) to 2 inch (51
mm) in diameter. Attach the
hat to the pipe with the U-
bolt, nuts, and rubber washers
provided (see diagram at left).
Then, insert the shorter
threaded end of the nylon
standoffs into the shield
body. Once in place, align the
other end of the standoffs to
the four corresponding holes
in the hat and secure with
nylon nuts. Ensure that the
sensor port
(the hole in the
side of the shield where the
air temperature and/or
humidity probe mounts)
faces the nearest global
pole (north for northern
hemisphere, south for
southern hemisphere) to
maximize shading of the
9