5. Software Configuration
5.3 Signal Generator and Remote Ports
The built-in signal generator can feed an output its signal to the DSP processing chain in order to perform
a spectral analysis and/or adjustment of parameters depending on the acoustic characteristics of the room
and equipment.
The parameters are:
• SIGNAL: Select type of signal desired (see Fig. 5-9)
- SINEWAVE (sinewave with a variable frequency)
- POLARITY (specific waveform to determine correct
polarity of the speakers, with variable frequency)
- WHITE NOISE
- PINK NOISE
• LEVEL: Set level for the signal.
• FREQUENCY: Set frequency of the sinewave or
polarity signal.
The REMOTE A and REMOTE B connectors allow you to simultaneously control the volume of one or
multiple inputs, or one or multiple outputs through a 10k-ohm potentiometer (0-10V DC). (see Fig. 5-10)
Remotes Screen
(see Fig. 5-10)
Each preset saves the function assigned to REMOTE A and
REMOTE B at the time the configuration is is saved (so that
different presets can contain different functions for either
REMOTE port).