Apollo 51000-601 Installatiehandleiding - Pagina 14

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Apollo 51000-601. Apollo 51000-601 15 pagina's. Wireless combination smoke, heat and carbon monoxide detector

• Battery (included): Two (2) Panasonic CR123A or Two (2) Energizer EL123AP
Lithium Batteries
• Regulatory Listing: Intertek ETL listed to UL 268 with supplementary heat
detection, UL 2075, ULC S529 with supplementary heat detection and ULCS588
standards
• Warranty: Two (2) years
• Included Accessories: Mounting Hardware Package
14. COMPATIBLE RF EQUIPMENT
14.1 MODEL 51000-600
Control Unit: Vivint CP04 (VS-SH2000-000) Doc 77-600022-001 – Rev A.2
Max Separation Range: 100 ft
14.2 MODEL 51000-601
Control Unit: Honeywell Lyric LCP500-L Doc 800-18078H 11/15 Rev. H
Max Separation Range: 100 ft
In typical single level and multilevel dwelling units and apartment buildings having
similar smoke alarm systems there is a possibility that signals sent by wireless
sensors may be blocked or reflected by metal before they reach the alarm Control
Panel, even if the signal path has been recently checked during a weekly test.
Blockage can occur if a metal object has been moved into the sensor's signal path.
15. REGULATORY INFORMATION NOTICE
Unauthorized changes or modifications could void the user's authority to operate
the equipment.
This device complies with Part 15 of the FCC Rules and Industry Canada license-
exempt RSS standard(s). Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired
operation of the device. This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/television technician for help
"For your information, The National Fire Alarm Code, NFPA 72, reads as follows:
"11.5.1 Required Detection."
"Where required by applicable laws, codes, or standards for a specific type of
occupancy, approved single- and multiple-station smoke alarms shall be installed
as follows:
1. In a sleeping rooms and guest rooms
2. Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any
door to a sleeping room, the distance measured along
a path of travel
3. On every level of a dwelling unit, including basements
4. On every level of a residential board and care occupancy (small facility),
including basements and excluding crawl spaces and unfinished attics
5. In the living area(s) of a guest suite
6. In the living area(s) of a residential board and care occupancy.
(Reprinted with permission from NFPA 72®, National Fire Alarm Code
Copyright © 2007 National Fire Protection Association, Quincy, MA 02269.
This reprinted material is not the complete and official position of the National Fire
Protection Association, on the referenced subject which is represented only by the
standard in its entirety.)
(National Fire Alarm Code® and NFPA 72
National Fire Protection Association, Inc., Quincy, MA 02269.)
are registered trademarks of the
®
APD0812 R1.6B