Preserving Signal Polarity with Negative Offset
To maintain your signal's original polarity while applying a negative DC offset, use the Scale
to first invert and attenuate your input signal as needed. Then, use the Slider to adjust the
positive DC offset to your desired level. Finally, take your signal from the -Out jack, which
provides an inverted output. This applies the negative DC offset and reverts the signal back
to its original polarity, delivering the negative offset without altering the phase.
14