3.
Main components
F1
Fuse for accessories protection 2 A
F2
Fuse for net and motor protection T5 A
SW1
Dip-switch control panel programming
SW2
Dip-switch control panel programming
SET
Button for receiver programming
Led showing all control panel connections (to be checked after turning the main power supply on)
DL1
It turns on when motor M1 starts and it flashes when motor slows down or for any other motor problem. (red)
DL2
It turns on when motor M2 starts and it flashes when motor slows down or for any other motor problem. (red)
DL3
It flashes when button SET is pressed for showing that remote control codes are going to be set or erased.
F.AP1
Always on, it turns off when limit switch opening motor M1 is activated (red)
F.CH1
Always on, it turns off when limit switch closing motor M1 is activated (red)
F.AP2
Always on, it turns off when limit switch opening motor M2 is activated (red)
F.CH2
Always on, it turns off when limit switch closing motor M2 is activated (red)
FOTO AP Always on, it turns off when photocells in opening/closing are activated (red)
FOTO
Always on, it turns off when photocells are activated (red)
STOP
Always on, it turns off when control stop is activated (red)
PED
Always off, it turns on when control pedestrian is activated (red)
START
Always off, it turns on when control start is activated (red)
If the led on the above schema don't correspond, please verify whether all wires are well connected and whether the devices are
working properly.
4.
Control panel programming and adjusting
The DIP-SWITCH SW1 and SW2 programming has to be done with the control panel disconnected (cut the main power
supply)
SW1
1
For working with just 1 motor use exit M1
2
Take off during start deactivated
SW2
Residential system active: during opening and break, the
1
control panel doesn't accept the control START; during closing
the gate stops and re-opens.
2
Pre-flashing of 3 seconds active
Working without limit switches, working time adjusted by
3
trimmer WORK.
Feature "close immediately". When all pairs of photocells
operate together at same time, after the obstacle has left the
entrance the gate will do as follow:
4
1.
with the residential system OFF, will close.
2.
with the residential system ON, will re-open and will
re-close after 2 seconds (if trimmer TCA is more then
zero).
5.
Trimmer WORK adjusting (working time and slowing down)
With limit switches: adjusting the trimmer WORK at zero (towards the position "-") both motors stop when the limit switches
operate. Adjusting the trimmer (towards the position "+") you select the slowing down time (from 0 to 6 seconds) after the limit
switches operate. In case the limit switches don't work properly, the maximum working time will be 60 seconds.
Without limit switches: trimmer Work controls the working time of motors (from 0 to 60 seconds). Selected time must be 3-4
seconds longer than real operating time of the gate.
6.
Trimmer DEL adjusting (leaves delay)
Trimmer DEL controls the opening delay of motor 2 from motor 1; adjustable from 0 to 15 seconds.
7.
Trimmer TCA adjusting (automatic shutting)
It controls the automatic shutting of the leaves (from 0 to 120 seconds). Adjusting the trimmer TCA towards the position "-" the
automatic shutting is deactivated. Any control STOP during the automatic shutting, automatically deactivates this feature.
8.
Trimmer POWER adjusting (motor power).
When motors are working, adjust the trimmer POWER in order to be able to stop the leaves with a power not higher than what the
actual standards and norms say (adjustable from 50% to 98% of motors power).
9.
Feature "close immediately".
This feature closes the gate immediately during opening or closing making a photocells check-up. This feature is selected
throughout the SW2 dip 4 = ON and with trimmer TCA more than zero. If the residential system is in OFF position, after the second
pair of photocells has been freed, the gate will close automatically. If the residential system is in ON position, when the second pair
of photocells has been freed, the gate will open completely and after a break of 2 seconds it will close.
10. How to set the remote control code
It is possible to set the remote control codes only when the gate is closed.
To set the code on the control START press and release the button SET, the led DL3 will start flashing. Send now the signal
pressing the button on the remote control you want to set in; the led on the panel will turn off showing the code has been accepted.
To set the code on the control PED (pedestrian) press and release the button SET, the led DL3 will start flashing. Send now the
signal pressing the button on the remote control you want to set in; the led on the panel will turn off showing the code has been
accepted.
11. how to erase all remote control codes
It is possible to set the remote control codes only when the gate is closed.
Keep pressed button SET until led DL3 lampeggia flashes and turns off.
4
WORK
DEL
TCA
POWER
RX
ON
ON
Working time and/or slowing down adjuster
Leaves delay adjuster
Automatic shutting adjuster
Motor power adjuster
Radio receiver integrated
For working with 2 motors use exit M1+ M2.
Take off during start activated (2 seconds)
Residential system off: during opening at any other control
START the gate stops; during closing the gate stops and re-
opens. Working step-by-step.
Pre-flashing off
Working with limit switches that control the slowing down
system adjustable by trimmer WORK
Feature "close immediately" off
OFF
OFF