AddSecure Edge VS5010 Gebruikershandleiding - Pagina 6
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} AddSecure Edge VS5010. AddSecure Edge VS5010 14 pagina's. Connect intercom
Ook voor AddSecure Edge VS5010: Gebruikershandleiding (10 pagina's)
7 Installation
7.1 Prerequisites
7.2 Installing the VS5010 terminal
7.2.1 Procedure
7.3 Installing the VS5051 terminal
7.3.1 Procedure
page 6
Before starting this procedure, make sure that all the items listed under
section 5, "Package Contents" are present and correct.
The main unit may only be installed in a locked elevator shaft where only
authorized elevator engineers have access.
Make sure there is enough space to open the main unit cover once the unit
is fixed in place.
This procedure covers the installation of the VS5000 circuit board inside an
approved alarm panel or cabinet enclosure and the connection of the
relevant alarm devices. The enclosure should be positioned in order to
ensure a good 4G signal and connection.
Step Action
1
Position and affix the VS5000 terminal in the enclosure using the
fixing kits supplied.
2
Connect cables from the alarm panels, voice panels and alarm
transmitters to the terminal PCBA to the appropriate connections,
see section 7.6 "Connecting voice panels and alarm transmitters"
below.
3
Finish this procedure by contacting the ARC to verify and test
alarm transmissions.
Note: Do not place the interface cables close to any power cables as
this could cause interference from electrical noise.
This procedure covers the mounting of the housing, with the PCB fixed
inside, in a suitable position.
Step Action
1
Affix the enclosure for the terminal in an appropriate place,
taking into consideration the routing of both the power and the
interface cables. Ensure that the interface cables are not close to
any power cables as this could cause interference from electrical
noise.
2
Position and affix the VS5000 terminal in the enclosure using the
fixing kits supplied.
PDK-13010-v.6.0 Edge VS5010 and VS5051 User manual