Firstly users connect converter board to PC through DB9 cable and open 'RF Tool', then insert module
into converter board. After that, the status column of 'RF tool' will give a indication 'Found Device'. Users
then can read/write the module.
If users connect USB converter, USB drive ''PL-2303_Driver_Installer''need be installed firstly. The
drive has different version for different OS. USB converter has five wires with five different colors: Black,
Red, Blue, Yellow. Black wire is GND pin. Red wire is VCC pin. Blue wire is TXD pin.
♦ Setting in circuit . Users also can use microcontroller to change the default parameters. The work
mechanism is the same as in PC.
Sync word
0xAF 0xAF
Notes: 1. The ID code is 0x00 0x00 in command.
RF1276
Figure 4: The connection diagram
ID code
Header
0x00
0x00
0XAF
RF1276 Command Structure
- 8 -
LoRa module
Command
Length
XX
YY
LEN
V3.0
Data
CRC
End code
XXXX
CS
0X0D 0X0A
2018-2-12