DURKOPP ADLER 0867 590124 Gebruiksaanwijzing - Pagina 11
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} DURKOPP ADLER 0867 590124. DURKOPP ADLER 0867 590124 16 pagina's. Fitting remaining thread monitor for var. kits
Anbauanleitung des Restfadenwächters
Instructions for fitting remaining thread monitor
3
Mounting the thread monitor
3.1 Replacing the counter-knife and the bobbin case, screwing the light barrier
1
3.2 Mounting the control unit and the valve
5
Ausgabe/Edition:
10.2006
für div. Bausätze (siehe Pkt 1.1)
for var. kits (see section 1.1)
Caution Danger of injury !
Turn off the main switch.
Replace the thread monitor only with the sewing machine
switched off.
–
Replace the "old" bobbin case against the "new" one.
–
Screw on the pre-assembled support 2, using the screw 1
and/or 3.
Note:
In general, the front edge of the light barrier should be
parallel to the front edge of the support 2.
–
Connect the hose 4 for the blower.
2
–
Set the position of the light barrier in a way that its beam goes
through the slit of the bobbin case and can be reflected back
by the bobbin surface again.
–
Put the spacers 6 (4x) in the remaining thread monitor
support plate and put on the printed circuit board 5.
–
Connect the cable to the circuit board of the thread monitor
7 = valve circuit board
8 = for the light barrier of the left needle
9 = for the light barrier of the right needle
6 (4x)
Printed in Federal Republic of Germany
7
8
9
Teile-Nr./ Part-No.:
0791 867702
3
4
Blatt:
von
Sheet: 11
from 16