SYMPTOM
CORRECT
FUNCTION
INDICATOR
Feed collides with
Dwell Reed Switch
dwell.
Output Indicator
All Indicators are
turns on with the
functioning cor-
first machine cy-
rectly except:
cle. Goes off and
Dwell Reed Switch
then back on with
Output and Feed
every cycle.
Solenoid Indica-
Feed Solenoid Indica-
t o r s a r e n o t
tor goes on and
c o m i n g o n i n
then back off with
the correct se-
every cycle.
quence.
Sluggish movement
All lights flash in
of the Feed.
sequence.
All Indicators are
functioning cor-
rectly.
Feed does not place
All lights flash in
weld pins on Up-
sequence.
per Weld Tip.
All Indicators are
functioning cor-
rectly.
POSSIBLE
ACTION
PROBLEM
D w e l l
R e e d
The Dwell Reed Switch activates the Feed Timer. If this switch is malfunc-
Switch.
tioning or out of position it will activate the feed at the wrong time. For
instructions on how to check and adjust, refer to the action section on
page 14 for "Possible Problem" Dwell Reed Switch. (Also refer to note
#4 on page 18.)
(A) Feed Speed
(A) Readjust the Feed Speed Control located on the air line going to the
Control.
Feed Cylinder.
(B) Air Lines.
(B) Check the Air Lines for leaks and water. If there is water in the Air
Lines, disconnect and blow out all Air Lines. Remove and clean the Ex-
haust Muffler. Reconnect the Air Lines and the muffler.
(C) Feed
(C) Turn the power and air off. Check the Feed Cylinder and the Pusher
Cylinder.
With Pawl for binding. Move the Pusher With Pawl in and out. The Pusher
With Pawl should move in and out with a slight resistance.
(D) Feed
(D) If the above procedures check out and the Feed still has sluggish
Solenoid.
movement the problem may be the Feed Solenoid. Remove the Air
Line from air inlet of the solenoid and spray a light oil into the solenoid.
Reconnect the Air Line and cycle the machine. If the Feed still has slug-
gish movement replace the Feed Solenoid.
(A) Feed Speed
(A) If the Feed Speed Control is open too much it may throw pins past
Control.
the Upper Weld Tip. Adjust Feed Speed Control so that it places the
pin on the Upper Weld Tip.
(B) Upper Weld
(B) Check the Upper Weld Tip for magnetism. Place a weld pin under the
Tip.
Upper Weld Tip. If the tip does not retain the pin or the magnets feel
weak replace the Upper Weld Tip.
( C ) Pu s h e r
(C) The pawl (hinged part) on the pusher may be damaged or missing. If
With Pawl.
so replace the Pusher With Pawl.
-15-