Elsea AWI50024 Gebruikershandleiding - Pagina 5

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Elsea AWI50024. Elsea AWI50024 13 pagina's.

GB
IINTRODUCTION
The purchased appliance taht you have is hightech product made
by a European company closely focused on research and
development exclusively in the professional dust/liquid vacuum
cleaner industry. This manual has been compiled to ensure a better
machine use. Please read it carefully and follow the instructions
contained in it. Thank you for having preferred our product. We
hope you will obtain satisfaction from using it.
GENERAL INFORMATION
1. This manual shall be considered ann integral part of the appliance
and should be carefully looked after for subsequent reference.
2. Take the appliance out of its packaging and make sure it is in
perfect condition, including accessories and optionals.
3. Make sure that the electrical data of the appliance, shown on the
label, corresponds to those of the mains supply.
4. The appliance must only be used with original accessories and
spare parts as these ensure safe and perfect operation.
5. The manufacturer disclaims all liability for injury to persons and
animals and damage to things due to the irresponsible use of the
appliance and to the use of non-original accessories and spare
parts.
6. The repair and/or replacement of the various component parts,
especially electrical parts, must be done by skilled persons.
7. The appliance is suitable for collective use (hotels, schools,
factories, shops, etc...)
IMPORTANT
Never use the machine in case of uncertainty or faults of any kind
l, including those not mentioned in this manual.

INSTALLATION

1. Check the position of the filter and head-tank fastening hooks.
Wrong filter positioning can cause serious damage to the machine.
2. Fit the hose to the vacuum connector, fit the required accessory
to the end of the hose.
3. Connect the power cable of the appliance to the power socket
with switches on "0" (OFF POSITION).
4. Empty the tank and remove the polyester filter in order to start
sucking liquids. Check if the blue sponge filter is clean and properly
assembled. This operation has to be made exclusively on the
models suitable for the suction of liquids.
5. Important: only refit the cloth filter to vacuum dusts, so as not to
cause problems to the appliance.
6. The noise level is below 85 dB(A)
OPERATION INSTRUCTIONS
1. Keep the ventilation areas and do not place objects, wrappings or
SAFETY PRECAUTIONS
caution: what to do
1. All power conduction parts must be protected agains water. SHORT-CIRCUIT RISK.
2. All jobs performed on the appliance, both routines and extraordinary, must always be done with the plug disconnected from the power supply.
3. Operation with a residual current circuit breaker provides extra protection for the operator (I n=30 mA).
4. Only ever use the appliance for the purposes for which it hase been designed and manufactured. ACCIDENT RISK.
5. In case of leakes of liquids, foams, etc., turn the appliance off straight away.
caution: what not to do
1. Do not leave the machine running and unguarded nor within reach of children, animals or persons that are not responsible for their own actions.
ACCIDENT RISK.
2. Do not vacuum inflammable combustion substance (eg: hot ashes), explosive and toxic substances, electrostatic or substances that are dangerous
for health. EXPLOSION OR POISONING HAZARD
3. Do not rest the vacuum inlet on or move this cose to delicate parts of the body (eyes, ears, mouth, etc.). ACCIDENT RISK.
4. Do not touch the plug and/or socket with wet hands. ELECTRIC SHOCK RISK.
5. Do not soak the appliance or spray it with liquid substances. SHORT-CIRCUIT.
6. In the case of extractor models, only use detergents compatible with vacuum and rilsan pipe covering materials. ACCIDENT RISK.
7. Do not pull or lift the appliance using the power cable. SHORT-CIRCUIT RISK.
PROBLEM
The machine does not start
The machine suddenly stops.
Reduced suction power.
Suction power suddenly drops.
anithing else on the machine before starting or during operation.
2. Reset the machine on a sound and stable surface.
3. Start the required machine operation by pressing the appropriate
switch (start motors, start extractor, power socket command for
electric tool, etc.).
IMPORTANT
1. The appliance features a floating valve that interrupts vacuum
when the tank is full. Switch off the appliance and empty the tank.
2. Do not use the appliance in case of malfunction, bad operation,
electrical parts non properly insulated. If necessary, contact your
authoryzed dealer.
3. Check regularly the power cable and if it is damaged, please
contact the manufacturer or the authorized technical service for the
replacement.

MAINTENANCE

1. Periodically remove and clean the vacuum filter. The cloth filter
can be washed in water and detergent; before using, it must be dry.
2. Replace the suction filter if there are holes, cuts or anomalies and,
however, at least once a year.
3. Check and free the blocked parts (vacuum pipes, connector,
brushes, etc.) from any deposited materials.
4. If necessary, clean the tank and in any case, never leave dust or
liquid residues in the tank for long periods.
IMPORTANT
Holes and/or cuts on the sides of the filter could allow transit of
materials and become the cause of serious damage to the applian-
ce.
PROBABLE CAUSE
No current
Because of overheating, the thermal protection turnes the
machine off (not available on all the machines).
Filter, nozzle, hose or tube clogged.
Tank full.
5
PROBABLE SOLUTION
Check main fuse, power cord,
plug and outlet.
After the machine has cooled down, you can start it
up again.
Check and clean
Stop the machine and empty the tank.
-