Datalogic DX6400 Snelle referentiehandleiding - Pagina 11

Blader online of download pdf Snelle referentiehandleiding voor {categorie_naam} Datalogic DX6400. Datalogic DX6400 17 pagina's.

Datalogic DX6400 Snelle referentiehandleiding

MECHANICAL INSTALLATION

The DX6400 reader can be positioned and installed in the best way possible as a result of the patented Step-A-
TM
Head
feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder
base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading
position. The reading head and the decoder base can be rotated independently from each other allowing the
installation even in the most critical locations.
To rotate the head follow the given procedure:
1.
detach the head from the base by unscrewing the four fixing screws;
2.
rotate the head in the desired position;
3.
loosen but don't remove the two screws on top of the head;
4.
affix the head onto the base carefully aligning the four fixing screws and
progressively tightening them about half-way;
5.
completely tighten the two screws on top of the head;
6.
completely tighten the four fixing screws.
The following diagrams give the overall dimensions of the reader and mounting bracket. They may be used for
their installation:
115.9
[4.56]
125.3
[4.93]
DX6400 Overall Dimensions
85
16.5
[3.35]
[0.65]
225.9
[8.89]
DX6400 QUICK GUIDE
Step-A-Head™ Feature
42
1.65
10
0.4
22
0.86
=
=
50
1.96
=
72
=
2.83
100
3.93
ST-237 Mounting Bracket Overall Dimensions
Head Screws
Fixing
Screw (4)
4
0.15
106°
73.2
2.88
mm
inch
11